Clinical Outcomes of Ripcord Removal Following A-Stream Glaucoma Shunt Implantation.
Young Hoon Hwang, Sharon Lee, Mijin Kim, Jaewan Choi
Central Seoul Eye Center, Seoul, Republic of Korea. · Central Seoul Eye Center, Seoul, Republic of Korea. deskshot@naver.com.
Key points
From the paper's conclusion- Ripcord removal in A-stream surgery provides significant additional IOP reduction, particularly in eyes with higher pre-removal IOP, while maintaining a favorable safety profile even with early intervention. A proactive, individualized approach to ripcord removal is recommended to optimize surgical outcomes.
Abstract
PURPOSE: To evaluate the clinical outcomes of ripcord removal following A-stream glaucoma shunt (A-stream; MICROT Inc., Seoul, Korea) implantation. METHODS: This retrospective study included 117 eyes that underwent A-stream implantation. The intraocular pressure (IOP)-lowering efficacy, safety of ripcord removal, and associated clinical factors were evaluated. Eyes undergoing removal were stratified by postoperative timing and pre-removal IOP levels. RESULTS: Ripcord removal was performed in 94 eyes (80.3%) at a mean of 67.8 ± 58.9 days. Eyes requiring removal had a significantly higher IOP at one month postoperatively than those that did not (13.7 ± 6.0 vs. 9.8 ± 4.8 mmHg; p=0.004). Following removal, the mean IOP decreased from 18.6 ± 6.7 to 11.6 ± 5.1 mmHg at one week, representing a 36.6% reduction (p<0.05), which remained significant through six months. A greater IOP reduction was associated with higher pre-removal IOP (p<0.05). There was high agreement (80.9%) between the 30-minute and 1-week post-removal IOP responses. The hypotony (IOP < 6 mmHg) rate at one week was 9.6% and was not associated with the removal interval or IOP level. Most cases of hypotony resolved spontaneously, except for one eye (1.1%) with uveitic glaucoma that required ripcord rethreading due to hypotony maculopathy. CONCLUSION: Ripcord removal in A-stream surgery provides significant additional IOP reduction, particularly in eyes with higher pre-removal IOP, while maintaining a favorable safety profile even with early intervention. A proactive, individualized approach to ripcord removal is recommended to optimize surgical outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Early Ripcord Removal and Short-Term Surgical Outcomes After A-stream Shunt Implantation in Primary Open-Angle Glaucoma.Journal of glaucoma · 2026
- A-stream Shunt Implantation for Secondary Glaucoma after Penetrating Keratoplasty: A Case Series.Korean journal of ophthalmology : KJO · 2026
- Ab-interno Ripcord Reinsertion for Overfiltration-related Hypotony After A-stream Glaucoma Shunt Surgery.Korean journal of ophthalmology : KJO · 2026
- Intraluminal stent removal after Paul glaucoma implant surgery: Intraocular pressure reduction and safety outcomes.Acta ophthalmologica · 2026
- Six-Month Surgical Outcomes of Ahmed ClearPath™ ST250 Implantation in Seven Eyes With Refractory Glaucoma: A Case Series.Cureus · 2026
- Safety and Efficacy of the Ahmed ClearPath versus Ahmed ClearPath Small Tube at Six Months: A Retrospective Comparative Cohort Study.Clinical ophthalmology (Auckland, N.Z.) · 2026