Ecancermedicalscience

Use of [18F]AlF-NOTA-Octreotide PET/CT as a diagnostic test for the detection of neuroendocrine tumours: a histopathology-referenced diagnostic accuracy study.

Paulina B Crespo-Morfin, Rodrigo Figueroa-Mendez, Eleazar Ignacio-Álvarez, Miguel A Ávila-Rodríguez, Alfredo A Reza-Albarrán

Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, 14080 Mexico City, Mexico.

Observational

Key points

From the paper's conclusion
  • 18F-OC PET/CT demonstrated high diagnostic performance for NET detection in a histopathology-referenced cohort. Given the logistical advantages of 18F production and distribution, this tracer may support broader access to somatostatin receptor PET imaging in settings where 68Ga-based tracers are constrained.

Abstract

BACKGROUND: Gallium-68-labeled somatostatin receptor positron emission tomography/computed tomography (PET/CT) is widely used for neuroendocrine tumour (NET) imaging, but implementation can be constrained by generator-dependent production and logistics. Fluorine-18 (18F) tracers may facilitate centralised production and broader access. We evaluated the diagnostic performance of [18F]AlF-NOTA-Octreotide (18F-OC) PET/CT for NET detection using histopathology as the reference standard. METHODS: In this cross-sectional diagnostic accuracy study, patients with suspected NET who underwent 18F-OC PET/CT and had histopathological confirmation were included. PET/CT positivity was defined a priori as standardised uptake value ≥8.3. We estimated sensitivity, specificity, predictive values, accuracy, likelihood ratios and 95% confidence intervals. RESULTS: Fifty-five patients were included (mean age 53.6 ± 15.1 years; 58.2% female). NET was confirmed in 39/55 (70.9%). PET/CT showed 92.3% sensitivity (36/39; 95% CI: 79.7-97.3) and 87.5% specificity (14/16; 95% CI: 64.0-96.5), with 94.7% positive predictive value, 82.4% negative predictive value and 90.9% accuracy. The positive likelihood ratio was 7.38, and the negative likelihood ratio was 0.09. False-negative cases were associated with small lesion size and/or biologically aggressive disease; false-positive cases showed mild uptake and were inflammatory on histopathology. CONCLUSION: 18F-OC PET/CT demonstrated high diagnostic performance for NET detection in a histopathology-referenced cohort. Given the logistical advantages of 18F production and distribution, this tracer may support broader access to somatostatin receptor PET imaging in settings where 68Ga-based tracers are constrained.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers