Achieving HbA1c Reduction in Diabetes Management : A Retrospective Comparison of Glucose Monitoring Methods.
Eshita Sharmin, Cameron Golden, Ejaz Mahmood
Bayhealth Family Medicine.
Key points
From the paper's conclusion- CGM use significantly improves glycemic outcomes for patients at-risk of developing HbA1c >9%, which supports broader CGM access for all patients with diabetes.
Abstract
OBJECTIVE: To evaluate the effectiveness of continuous glucose monitoring (CGM) compared to point-of-care (POC) glucose testing in reducing HbA1c among adults with diabetes. METHODS: This single-center, retrospective cohort study included adult patients with type 1 or type 2 diabetes attending Bayhealth Sussex Endocrinology Clinic between January 1, 2023 and December 31, 2024. Controls were POC testers, while the intervention group was CGM users. Data was extracted from Epic electronic medical records via SlicerDicer and chart review. Exclusion criteria included pregnancy, terminal illnesses (i.e. end-stage renal disease, cancer), and medications affecting CGM accuracy (i.e. hydroxyurea, ascorbic acid). The primary endpoint was change in HbA1c from baseline to 3- and 6-month follow-ups. Secondary endpoints included estimated average glucose (eAG) and CGM metrics (time sensor active, time in range (TIR), time above range (TAR)). RESULTS: Of 90 patients, 63 used CGM and 27 were POC testers. Baseline characteristics were similar between the groups, though CGM patients had higher comorbidity burden and insulin use. CGM users achieved significantly greater HbA1c reduction than POC testers (-1.8% vs. -1%; p < 0.001). Improvements were most pronounced among patients with baseline HbA1c ≥9% (time sensor active of -2 with p = 0.227, TIR 13.4 with p = 0.43, high TAR -8.7 with p = 0.344, very high TAR 1.9 with p = 0.455) but significant among baseline HbA1c 7-9% (time sensor active of -1.5, TIR -3.6, high TAR 1.9, very high TAR -1, with p < 0.001 for all metrics). CGM compliance maintained high (81.9% at 3 months vs. 75.4% at 6 months, p = 0.021) with notable improvement of time-in-range (TIR) (1.8, p = 0.002). CONCLUSION: CGM use significantly improves glycemic outcomes for patients at-risk of developing HbA1c >9%, which supports broader CGM access for all patients with diabetes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Continuous Glucose Monitoring Frequency and Glycemic Control in People With Type 2 DiabetesJAMA Network Open · 2025
- Factors Associated with HbA1c-Lowering in a Randomized Trial of Continuous Glucose Monitoring in Adults with Non-Insulin-Treated Diabetes: An Observational Analysis.Canadian journal of diabetes · 2026
- Continuous glucose monitoring versus self-monitoring of blood glucose in individuals with type 2 diabetes: a randomised, multicentre, open-label, superiority trialThe Lancet Diabetes & Endocrinology · 2026
- Observational study of the relationship between the use of real-time continuous glucose monitoring and glycemic control in patients with diabetes in Japan: the REALJ study.Endocrine journal · 2026
- Effectiveness of Continuous Glucose Monitoring in Non-Intensively Managed Type 2 Diabetes: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.Journal of diabetes science and technology · 2026
- Evaluation of continuous glucose monitoring outcomes and health care resource utilization in patients with non-insulin-treated type 2 diabetes.Journal of managed care & specialty pharmacy · 2026