AJNR. American journal of neuroradiology

Dual Energy Photon-Counting Detector CT for Spinal Bone Marrow Edema Imaging.

Ajay A Madhavan, Lifeng Yu, Peter G Kranz, Timothy J Amrhein, Michelle L Kodet, Francis Baffour, Nikkole Weber, Felix E Diehn

From the Division of Neuroradiology, Department of Radiology (A.A.M., P.G.K., T.J.A.), Duke Health, 2301 Erwin Rd, Durham, NC 27710 and Division of Neuroradiology, Department of Radiology (L.Y., M.L.K., F.B., N.W., F.E.D.), Mayo Clinic, 200 First St SW, Rochester, MN 55905 ajay.madhavan@duke.edu. · From the Division of Neuroradiology, Department of Radiology (A.A.M., P.G.K., T.J.A.), Duke Health, 2301 Erwin Rd, Durham, NC 27710 and Division of Neuroradiology, Department of Radiology (L.Y., M.L.K., F.B., N.W., F.E.D.), Mayo Clinic, 200 First St SW, Rochester, MN 55905.

Key points

From the paper's conclusion
  • We also illustrate two of our early examples of bone marrow edema detection using this technique, demonstrating that this technique successfully identified areas of bone marrow edema and were concordant with MRI findings.

Abstract

Photon-counting detector (PCD) CT is an emerging technology with several applications in neuroradiology. In the spine, most recent studies have focused on detection of spinal CSF leaks and vascular imaging, largely because these applications benefit from high spatial resolution. However, PCD CT also confers inherent spectral sensitivity that may support additional applications. Spectral applications of PCD CT have been less extensively described, with prior uses including reduction in metallic hardware artifact and accentuation of contrast attenuation for spinal CSF leak detection. One potential use that has not yet been detailed is the detection of bone marrow edema to help characterize the age and healing status of vertebral body compression fractures. PCD CT has the unique ability to perform material decomposition by using spectral information both from the PCD's intrinsic energy-resolving capabilities and from the use of dual-energy acquisition. This functionality may be particularly useful for bone marrow edema imaging, which is a relatively more complex material decomposition task. In this technical report, we describe specific scanning and reconstruction parameters on PCD CT to perform dual-source, dual-kV bone marrow edema imaging in the spine. We also illustrate two of our early examples of bone marrow edema detection using this technique, demonstrating that this technique successfully identified areas of bone marrow edema and were concordant with MRI findings.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Dual Energy Photon-Counting Detector CT for Spinal Bone Marrow Edema Imaging — Science Skim