Diagnostic Performance of Arterial Spin-Labeling MRI in the Presurgical Evaluation of Focal Epilepsy and the Limits of Current Evidence for Predicting Surgical Outcome: A Systematic Review and Meta-Analysis.
Enrico Michele Salamone, Eleonora Grande, Augusto Di Castelnuovo, Giancarlo Di Gennaro, Marcello Bartolo, Diego Centonze, Marco Ciavarro, Andrea Bartolo
From the IRCCS Neuromed (E.M.S., E.G., G.D.G., M.B., D.C., M.C., A.B.), Research Unit of Epidemiology and Prevention (A.D.C.), IRCCS Neuromed, Pozzilli (IS), Italy. · From the IRCCS Neuromed (E.M.S., E.G., G.D.G., M.B., D.C., M.C., A.B.), Research Unit of Epidemiology and Prevention (A.D.C.), IRCCS Neuromed, Pozzilli (IS), Italy. andreabartolo@neuromed.it.
Key points
From the paper's conclusion- ASL has moderate, stable sensitivity for identifying perfusion abnormalities concordant with the anatomo-electro-clinically defined EZ, whereas specificity is not estimable from current single-group designs. ASL-linked surgical cohorts achieve seizure freedom in two-thirds of operated patients, but whether ASL-resection concordance predicts seizure freedom is unquantifiable: a reporting gap, not a null result. Until outcome is reported stratified by ASL-resection concordance, ASL should be used as a localizing adjunct, not a prognostic marker.
Abstract
BACKGROUND AND PURPOSE: Arterial spin-labeling (ASL) MR imaging is a noninvasive perfusion technique used in presurgical evaluation of focal epilepsy. A 2021 meta-analysis assessed its accuracy for identifying perfusion abnormalities concordant with the epileptogenic zone (EZ) but predated later studies and partly derived specificity from healthy-control true negatives. We re-estimated the diagnostic accuracy of ASL for EZ-concordant perfusion abnormalities with explicit handling of true negatives, and tested whether current data permit a quantitative estimate of the relationship between ASL findings and postsurgical seizure freedom. MATERIALS AND METHODS: Following PRISMA 2020 and PRISMA-DTA, we searched PubMed, Embase, Cochrane CENTRAL, and Scopus from inception to June 2026 for English-language primary studies (≥10 patients) of ASL for EZ localization or surgical-outcome evaluation in focal epilepsy. Random-effects models estimated pooled sensitivity (logit; primary), an exploratory specificity, a logit concordance/detection proportion, and a Freeman-Tukey seizure-free proportion. Because true negatives were absent by design, a joint bivariate/HSROC model was not estimable. Risk of bias used QUADAS-2 and QUIPS; certainty of evidence used a DTA-adapted GRADE approach. RESULTS: Fifteen studies were included. The primary analysis (8 studies, 160 patients) yielded a pooled ASL sensitivity for EZ-concordant abnormalities of 0.73 (95% CI, 0.65-0.80; I2 = 0.0%). The concordance/detection proportion was 0.78 (95% CI, 0.62-0.89; 4 studies), and exploratory specificity 0.37 (95% CI, 0.13-0.71; 5 studies). In the surgical-outcome arm, the pooled seizure-free proportion (Engel I/ILAE 1) was 0.68 (95% CI, 0.58-0.77; 4 studies) and 0.71 (95% CI, 0.56-0.84) in a stricter analysis. Critically, a pooled odds ratio for seizure freedom in ASL-concordant versus ASL-discordant resections could not be computed: the required cross-tabulation was reported in no study. CONCLUSIONS: ASL has moderate, stable sensitivity for identifying perfusion abnormalities concordant with the anatomo-electro-clinically defined EZ, whereas specificity is not estimable from current single-group designs. ASL-linked surgical cohorts achieve seizure freedom in two-thirds of operated patients, but whether ASL-resection concordance predicts seizure freedom is unquantifiable: a reporting gap, not a null result. Until outcome is reported stratified by ASL-resection concordance, ASL should be used as a localizing adjunct, not a prognostic marker.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of the Consistency of Peri-ictal Hemodynamic Findings Revealed by Capturing More Than 3 Seizures Using 1.5-Tesla Pseudo-continuous Arterial Spin Labeling Magnetic Resonance Perfusion Imaging with Triple Post-labeling Delays: Report of 3 Cases.NMC case report journal · 2026
- Non-contrast MRI reliably captures perfusion abnormalities in status epilepticus.Epilepsia · 2026
- Multimodal neuroimaging fusion in presurgical evaluation of drug-resistant epilepsy: current evidence, clinical integration, and future directions.Frontiers in neuroscience · 2026
- Non‐Contrast Assessment of Blood–Brain Barrier Permeability to Water: Improved Signal Modeling and Data AcquisitionMagnetic Resonance in Medicine · 2025
- Assessing cognitive impairment in epilepsy using Arterial spin-labeled (ASL) perfusion imaging.Brain imaging and behavior · 2026
- Peri-ictal Hyperperfusion Revealed by Arterial Spin Labeling Perfusion Images in 2 Patients with Post-aneurysmal Subarachnoid Hemorrhage Epilepsy and Associated Old Infarction in the Middle Cerebral Artery Territory.NMC case report journal · 2026