Clinical Imaging of 225Ac in a PET Scanner via Time-of-Flight Cascade γ-Ray Imaging.
Javier Caravaca, Youngho Seo, Jorge Cabello, Stefan B Siegel, Robert R Flavell, Thomas A Hope
Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, California; jcaravacarodriguez@lbl.gov. · Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California; and.
Key points
From the paper's conclusion- We propose an alternative nuclear imaging modality that enables imaging of 225Ac in PET scanners: time-of-flight cascade γ-ray imaging (TOF-CGI).
Abstract
Clinical imaging of the α-therapy radionuclide 225Ac and its progeny has proven challenging with SPECT because of low detection efficiency and a poor signal-to-noise ratio (SNR). We propose an alternative nuclear imaging modality that enables imaging of 225Ac in PET scanners: time-of-flight cascade γ-ray imaging (TOF-CGI). Methods: We leveraged the time and position information of the γ-rays emitted in a fast cascade during the decay of 225Ac daughter 209Tl to produce 3-dimensional images of the spatial distribution of the emissions. We characterized this imaging modality with vials, evaluated it with clinical-size phantoms, and performed a pilot imaging experiment with a patient with prostate cancer injected with [225Ac]Ac-PSMA-617. Results: Imaging of vials confirmed good activity quantification linearity, minimum detectable activity of 5.5 kBq for a 20-min scan, and a spatial resolution of approximately 20 mm full width at half maximum transversally and 42 mm full width at half maximum axially. A phantom filled with a concentration of 44 kBq/mL revealed a higher SNR than did SPECT with a 10-fold-shorter scan time. The TOF-CGI sensitivity with the phantom was 26.0 cps/MBq, and the detection efficiency was an order of magnitude higher with TOF-CGI than with SPECT. TOF-CGI of the patient demonstrated activity within a known tumor in the prostate bed and higher SNR than that of SPECT. Conclusion: We demonstrated the feasibility of 225Ac tomography in a PET scanner via TOF-CGI, opening a window for application in other targeted radionuclide therapies. This technique enables imaging of nonpositron emitters in PET scanners and establishes an imaging paradigm complementary to SPECT. Implementation of image corrections and usage of long-axial-field-of-view PET scanners may further improve its sensitivity, resolution, and SNR.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- In vivo Quantitative Tomography of 225Ac Daughters in a Prostate Cancer Mouse Model with a Compton CamerabioRxiv · 2026
- Quantitative SPECT imaging of 225Ac and its daughters in mice in vivo.Medical physics · 2026
- Can $^{225}$Ac be imaged on a long axial field-of-view PET/CT with standard clinical settings?arXiv · 2026
- Quantitative Comparison of SPECT and PET Performance for Clinical Theranostic ApplicationsJournal of Nuclear Medicine · 2025
- Influence of Radionuclide Cascade Decay Characteristics on Non-Collinear Coincidence Imaging Performance: A GATE-Based Monte Carlo Simulation Study.Biomedical physics & engineering express · 2026
- 134Ce/134La Radiotheranostics from PET Surrogation of 225Ac to Auger and Conversion-Electron Therapy.Molecular pharmaceutics · 2026