Reliability of a Standardized Isokinetic Knee Strength Protocol Across a Slow-Fast Velocity Spectrum in Physically Active Adults with the Biodex System 4 Pro.
Jesper Augustsson, Jannie Strågegård, Elin Peterson, Ted Gunhamn
Department of Sport Science Linnaeus University.
Key points
From the paper's conclusion- The isokinetic measurements were reliable at both 90°/s and 180°/s, supporting their use in rehabilitation and strength training evaluations. As distinct strength qualities exist and muscle performance can be assessed across a dynamic velocity spectrum, isokinetic testing at multiple angular velocities may provide a more comprehensive characterization of muscle function than a single-speed assessment alone.
Abstract
BACKGROUND: Isokinetic dynamometry is widely used to assess knee muscle strength in both clinical and athletic settings; however, the reliability of measurements across different angular velocities representing distinct regions of the force-velocity spectrum requires further investigation. Purpose: To examine the test-retest reliability of concentric isokinetic knee extension and flexion strength at slow and fast angular velocities using the Biodex System 4. STUDY DESIGN: Repeated measures. METHODS: A total of 15 healthy, physically active adults, women (n=7) and men (n=8), within the age range 21-34 years (inclusion criterion: 18-40 years) participated in the study. Each subject completed two test sessions spaced one week apart. Peak torques of the dominant leg during knee extension and flexion were measured using the Biodex System 4 at angular velocities of 90°/s and 180°/s. Reliability was analyzed using intraclass correlation coefficient (ICC) with 95% confidence intervals and the coefficient of variation (CV). RESULTS: The results showed high to very high reliability across all test conditions (ICC = 0.92-0.99; 95% CI: 0.78-1.00). CV values ranged from 2.7% to 4.2%, and no significant differences in peak torque were observed between test sessions. CONCLUSION: The isokinetic measurements were reliable at both 90°/s and 180°/s, supporting their use in rehabilitation and strength training evaluations. As distinct strength qualities exist and muscle performance can be assessed across a dynamic velocity spectrum, isokinetic testing at multiple angular velocities may provide a more comprehensive characterization of muscle function than a single-speed assessment alone. LEVEL OF EVIDENCE: 2.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Load Range During Isokinetic Knee Extension and Flexion Exercise in Strength-Matched Male and Female Collegiate Athletes.Journal of strength and conditioning research · 2026
- Developing bespoke isokinetic dynamometer protocols to replicate the functional demands of (p)rehabilitative screening tasks.Research in sports medicine (Print) · 2026
- Quantifying Recovery After Anterior Cruciate Ligament Reconstruction Using the Torque- Velocity Relationship.Journal of visualized experiments : JoVE · 2026
- Comparison of Standing, Prone, and Sitting Protocols for Knee Joint Position Sense Testing in Non-Athletic Adolescent Females: A Non-Weight-Bearing Open Kinetic Chain Study.Journal of functional morphology and kinesiology · 2026
- Reliability of multilevel functional data in resistance training biomechanics - a pointwise mixed-modelling approach.Journal of biomechanics · 2026
- Test–Retest Reliability of Maximal and Rapid Knee Extensor Force Production: Influence of Verbal Instruction and Trial Selection CriteriaScandinavian Journal of Medicine and Science in Sports · 2026