International Journal of Drug Delivery TechnologyOpen accessAscorbic acid

Development and Validation of RP-HPLC Method for Simultaneous Estimation of Resveratrol, Quercetin, and Ascorbic Acid in Combined Pharmaceutical Formulation

Key points

From the paper's conclusion
  • The present research work describes the development and validation of a reliable Reverse Phase High Performance Liquid Chromatography (RP-HPLC) method for simultaneous estimation of Resveratrol, Quercetin and Ascorbic Acid in combined pharmaceutical formulation.The method was optimized using a C18 column with an appropriate mobile phase composition (Methanol: Water, 50:50), flow rate of 0.800 mL/m

Abstract

The present research work describes the development and validation of a reliable Reverse Phase High Performance Liquid Chromatography (RP-HPLC) method for simultaneous estimation of Resveratrol, Quercetin and Ascorbic Acid in combined pharmaceutical formulation.The method was optimized using a C18 column with an appropriate mobile phase composition (Methanol: Water, 50:50), flow rate of 0.800 mL/min and detection wavelength to achieve efficient separation and accurate quantification.Detection was carried out at 210 nm, where all three analytes showed adequate absorbance.The chromatographic conditions provided well-resolved peaks with acceptable retention times and system suitability parameters.The developed method was validated as per ICH Q2 (R1/R2) guidelines.Linearity was established over selected concentration ranges 5-25 µg/mL of Resveratrol, 1-5 µg/mL Quercetin and 6-30 µg/mL Ascorbic Acid with correlation coefficients 0.9995 for three drugs.LOD and LOQ for Resveratrol, Quercetin and Ascorbic Acid was found to be 1.59, 0.32 and 1.91 and 4.83, 0.97 and 5.79 µg/mL respectively.Accuracy was confirmed through recovery studies, which results found to be 97.17-98.90for Resveratrol, 97.50-98.77for Quercetin and 95.73-97.88 for Ascorbic Acid.Percentage assay was found to be 98.07 for Resveratrol, 97.48 for Quercetin and 98.53 for Ascorbic Acid.Robustness studies confirmed that minor variations in analytical conditions did not significantly affect the performance of the method.Overall, the developed RP-HPLC method is simple, accurate, and suitable for routine analysis and quality control of combined formulations containing Resveratrol, Quercetin, and Ascorbic Acid.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Development and Validation of RP-HPLC Method for Simultaneous Estimation of Resveratrol, Quercetin, and Ascorbic Acid in Combined Pharmaceutical Formulation — Science Skim