International Journal of Drug Delivery TechnologyOpen accessCadaveric spasm

Morphological Study of the Tricuspid Valve in Human Embalmed Hearts

Key points

From the paper's conclusion
  • Materials and Methods:A descriptive cross-sectional anatomical study was conducted at Father Muller Medical College, Mangalore, Karnataka, on 50 embalmed human cadaveric hearts.Annular circumference, valve diameter, and the length and height of each leaflet were measured using a thread-and-scale method and measuring tape.Descriptive statistics including mean, standard deviation, and range were cal

Abstract

Background: The tricuspid valve, situated between the right atrium and right ventricle, is a vital component of cardiac anatomy whose morphological variability has significant implications for surgical and interventional cardiac procedures.Anatomical knowledge of its three leaflets-anterior, posterior, and septal-is indispensable for effective valve repair, prosthetic valve design, and understanding functional tricuspid regurgitation.Aims & Objectives: To measure and compare the annular circumference, leaflet length, and leaflet height of the anterior, posterior, and septal leaflets of the tricuspid valve in human embalmed cadaveric hearts, and to establish normative morphometric data relevant to clinical and surgical practice. Materials and Methods:A descriptive cross-sectional anatomical study was conducted at Father Muller Medical College, Mangalore, Karnataka, on 50 embalmed human cadaveric hearts.Annular circumference, valve diameter, and the length and height of each leaflet were measured using a thread-and-scale method and measuring tape.Descriptive statistics including mean, standard deviation, and range were calculated for all parameters.Results: The annular circumference ranged from 8.9 to 15.3 cm (mean ± SD: 11.84 ± 1.42 cm) and valve diameter from 2.83 to 4.87 cm (mean: 3.75 ± 0.48 cm).The anterior leaflet was consistently the largest with a mean length of 4.82 ± 0.83 cm and height of 2.04 ± 0.23 cm.The septal leaflet showed intermediate dimensions, while the posterior leaflet was the smallest and most variable.Conclusion: Significant morphometric variability exists in the tricuspid valve across cadaveric specimens.The anterior leaflet was the largest in all measured parameters, while the posterior leaflet demonstrated the greatest variability.These findings provide normative data of practical value for cardiac surgeons, interventional cardiologists, and biomedical engineers involved in prosthetic valve design.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers