Transcatheter aortic valve implantation with Vitaflow prosthesis in Latin America.
Juan G Chiabrando, Verónica González, Alfredo Rodríguez, Germán Cafaro, Marcelo Menéndez, José Lazarte, Agustín Hauqui, Oscar Mendiz,
Department of Interventional Cardiology, Sanatorio Anchorena, Buenos Aires, Argentina. · Department of Interventional Cardiology, Sanatorio Otamendi, Buenos Aires, Argentina.
Key points
From the paper's conclusion- In a Latin American population, the Vitaflow TAVI valve has proved good safety and efficacy outcomes at 12 months of follow-up in the treatment of patients with severe aortic stenosis.
Abstract
BACKGROUND: Robust long-term data on the performance and durability of novel transcatheter aortic valve implantation (TAVI) valve designs, especially in Latin America, are lacking and warrant further investigation. OBJECTIVES: To provide a 1 year follow-up data regarding a novel TAVI device. METHODS: A retrospective, multicenter cohort study was conducted in Latin America of patients with severe symptomatic aortic stenosis treated with the Vitaflow prosthesis from June 2022 to June 2023. The clinical endpoints were all-cause death, cardiovascular death, myocardial infarction, stroke, vascular and bleeding complications, permanent pacemaker implantation (PPM), and heart failure admission. Echocardiographic outcomes were the transvalvular gradient and paravalvular leak at 1 year of follow-up. RESULTS: A total of 46 consecutive patients were included. The mean age of the patients was 80.9 ± 6.13 years; 50% were men, the mean STS score was 4.64 ± 2.67, and 60.8% were in NYHA class III/IV. The most used valve size was the 27 mm (47.1%). All-cause death at 1-year follow-up occurred in 4 patients (8.7%), of which 3 were cardiovascular (6.5%). There were 2 strokes, 1 vascular event, 2 major bleeding events, 4 new PPMs, and no myocardial infarctions or heart failure admissions. The 1-year mean transvalvular gradient was 7 ± 4 mmHg, and 3 patients (6.4%) had moderate paravalvular leak, with no severe leaks. CONCLUSIONS: In a Latin American population, the Vitaflow TAVI valve has proved good safety and efficacy outcomes at 12 months of follow-up in the treatment of patients with severe aortic stenosis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical Outcomes and Valve Performance of Intra-Annular Self-Expanding Transcatheter Aortic Valve in Valve-in-Valve Procedures: Insights From the NAViV Registry.Journal of the American Heart Association · 2026
- Clinical Outcomes of the Allegra Transcatheter System in Bioprosthetic Aortic Valve Failure: A Multicentre Valve-in-Valve Registry.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Short- and Long-Term Outcomes After Transcatheter Aortic Valve Implantation With Large Self-Expanding Valves.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Five-Year Follow-Up of Transcatheter Aortic Valve Replacement With Self-Expanding Intra-Annular Versus Commercially Available Valves.JACC. Cardiovascular interventions · 2026
- Long-Term Outcomes of a Self-Expanding Transcatheter Heart ValveStructural Heart · 2026
- One-Year Outcomes of Myval Versus Contemporary Transcatheter Heart Valves in Severe Aortic Stenosis: A Systematic Review and Meta-Analysis.Cardiology in review · 2026