Workstation-worker geometric mismatch and breathing-zone exposure in local exhaust ventilation: a structured narrative review.
Ji-Min Kim, Sun-Haeng Choi, Dal-Jae Park
Graduate School of Safety Engineering, Seoul National University of Science and Technology, Republic of Korea. · Department of Occupational and Environmental Medicine, College of Medicine, Chungbuk National University, Republic of Korea.
Key points
From the paper's conclusion- This structured narrative review introduces workstation-worker geometric mismatch-the spatial misalignment among contaminant source, hood opening, work surface, worker body, and breathing zone-as a unifying exposure-control construct.
Abstract
Local exhaust ventilation (LEV) is a principal engineering control for capturing contaminants at the source, yet its performance is conventionally judged by face velocity, capture velocity, sash height, and exhaust flow rate, parameters mostly verified in routine practice under static, worker-free conditions that do not reliably predict breathing-zone concentrations. This structured narrative review introduces workstation-worker geometric mismatch-the spatial misalignment among contaminant source, hood opening, work surface, worker body, and breathing zone-as a unifying exposure-control construct. Because the evidence spans tracer-gas, wind-tunnel, flow-visualization, computational fluid dynamics, and methodological studies, no pooled effect size was estimated; instead, 40 publications (31 primary experimental or numerical investigations and 9 review or methodological papers) were synthesized according to five mechanistic pathways: worker wake and reverse flow; source-breathing-zone distance; sash and hood-opening geometry; posture, orientation, and movement; and the human thermal plume. Nominal velocity repeatedly failed to guarantee breathing-zone protection, and human presence, proximity, movement, and body heat could overwhelm apparently adequate static designs, although evidence directness differs across mechanisms. The worker should therefore be treated not as an external user of LEV but as an active aerodynamic and thermal component within it, supporting worker-centred, geometry-aware evaluation, certification, and training.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Spatial Intelligence for Indoor Air Quality: Integrating Spatial Uncertainty Into Monitoring, Exposure Assessment, and Ventilation ControlIndoor Air · 2026
- Influence of a local ventilation system on patient and personnel protection in operating roomsJournal of Hazardous Materials · 2025
- Multi-Scale Computational Fluid Dynamics Investigation of Ventilation-Controlled and Gravity-Controlled Respiratory Aerosol Transport in an Office Environment: Implications for Heating, Ventilation, and Air Conditioning Design and Airborne Infection MitigationBuildings · 2026
- Comparison of Trajectory-Integrated, Stationary, and Wearable Methods for Estimating Thermal Exposure of Factory Workers: Associations Among Thermal Exposure, Fatigue, Thermal Sensation, and Workload.Sensors (Basel, Switzerland) · 2026
- The Synergy of Ventilation System Layouts and Occupant Arrangements on Ventilation Effectiveness: A Case Study in a Shared OfficeBuildings · 2025
- Towards the experimental assessment of exposure to extremely low frequency magnetic field.Physics in medicine and biology · 2026