Brush- and spike-type perch deterrents at power lines present an entrapment mortality risk for raptors: examples from Mongolia

Amartuvshin Purevdorj, Andrew Dixon

Key points

From the paper's conclusion
  • We report an additional risk of entrapment mortality posed by brush- and spike-type perch deterrents on 10-kV and 15-kV power poles.

Abstract

The misapplication of grounded brush- and spike-type avian perch deterrents at electricity distribution line poles is known to increase the risk of avian electrocution through displacement of birds to more dangerous perch sites closer to energised conductors, and by increasing the area of grounded metal for a bird to make simultaneous contact with an energised conductor. We report an additional risk of entrapment mortality posed by brush- and spike-type perch deterrents on 10-kV and 15-kV power poles. During power line surveys across 11 provinces of Mongolia in 2013–15 and 2018, we observed 20 instances in which the carcasses of small and medium-sized birds of prey were hanging from perch deterrents affixed on crossarms. While it was not possible to discount electrocution as the cause of death for medium-sized raptors, entrapment was most likely the cause of death for smaller raptors, owls and corvids. We recommend removing grounded brush- and spike-type perch deterrents from the crossarms of electricity distribution line poles.