Minerva urology and nephrology

Robot-assisted radical nephrectomy with caval thrombectomy: surgical set-up and technical considerations from the first two cases using the Hugo™ RAS System.

Rocco Papalia, Francesco Tedesco, Angelo Civitella, Alberto Ragusa, Roberto Cirillo, Marco Fantozzi, Giuseppe Simone, Francesco Prata

Department of Urology, Fondazione Policlinico Universitario Campus Bio-Medico di Roma, Rome, Italy. · Research Unit of Urology, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, Rome, Italy.

Key points

From the paper's conclusion
  • This initial experience suggests the technical feasibility of RARN with IVC thrombectomy using the Hugo™ RAS system in highly selected cases. A standardized surgical set-up and procedural workflow for a highly complex was described.

Abstract

BACKGROUND: The surgical management of renal cell carcinoma (RCC) with inferior vena cava (IVC) tumor thrombus remains challenging. Published experiences have been limited to da Vinci®-based series. We report our step-by-step surgical setting and technique for robot-assisted radical nephrectomy (RARN) with IVC thrombectomy performed using the Hugo™ Robotic-Assisted Surgery (RAS) system. METHODS: From September 2025 to October 2025, two highly selected patients with right-sided clear-cell RCC and Mayo level II IVC tumor thrombus, both presenting with distant metastatic disease at diagnosis underwent RARN and IVC thrombectomy using the Hugo™ RAS system after upfront systemic therapy. The procedure illustrated in the accompanying video involved sequential left renal vein, infrarenal, and infrahepatic IVC clamping, followed by cavotomy, en bloc thrombus removal, and subsequent caval reconstruction. Baseline demographic and pathological characteristics, 30- and 90-day postoperative outcomes, and early oncological findings at last follow-up were assessed. RESULTS: Docking and console times were 9 and 340 minutes for the first case and 8 and 311 minutes for the second case, respectively. Estimated blood loss was 500 mL in the first case and 350 mL in the second case. On postoperative day 4, both patients were discharged. Surgical margins were negative. Final pathology confirmed clear-cell RCC in both cases. No intra- or postoperative complications or 30-day readmissions were recorded. At 90-day follow-up, contrast-enhanced CT confirmed caval patency in both patients, with no local recurrence, disease progression, or mortality. CONCLUSIONS: This initial experience suggests the technical feasibility of RARN with IVC thrombectomy using the Hugo™ RAS system in highly selected cases. A standardized surgical set-up and procedural workflow for a highly complex was described.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers