Sikri's Magnetic Attachment Retained Two-Tray (SMART) impression technique for prosthodontic management of a knife-edge residual ridge: a case report.
Arpit Sikri, Jyotsana Sikri, Rekha Thiruvengadam, Muthu Thiruvengadam
Department of Prosthodontics and Crown & Bridge, Punjab Government Dental College and Hospital, Amritsar, Punjab, India. · Department of Conservative Dentistry & Endodontics, Bhojia Dental College & Hospital, Budh (Baddi), Teh. Baddi, Distt. Solan, Himachal Pradesh, India.
Key points
From the paper's conclusion- The SMART impression technique represents a simple, innovative, and clinically applicable approach for the prosthodontic management of mandibular knife-edge residual ridge. By eliminating manual tray stabilization and minimizing tissue displacement during impression making, it facilitates accurate mucostatic impressions and may improve denture fit, stability, and overall clinical performance. Further clinical studies involving larger patient populations are required to evaluate its reproducibility and long-term clinical effectiveness.
Abstract
BACKGROUND: Mandibular knife-edge residual ridges present a significant challenge during complete denture impression making because of their narrow morphology and susceptibility to tissue distortion under pressure. This report describes the clinical application of the novel Sikri's Magnetic Attachment Retained Two-Tray (SMART) impression technique, conceptualized, developed, and patented by Dr. Arpit Sikri (Patent/ROC No. L-156844/2024), for obtaining an accurate mucostatic impression of a mandibular knife-edge residual ridge without the application of manual finger pressure. The SMART technique employs a magnetically retained split custom tray design that facilitates pressure-free tray stabilization and precise impression making in anatomically challenging mandibular residual ridges. MATERIALS AND METHODS: A completely edentulous patient with a pronounced knife-edge residual ridge in the anterior mandible was rehabilitated using the SMART impression technique. A custom-designed split two-part impression tray incorporating magnetic attachments for self-retention and retentive holes for impression material retention was fabricated. Magnetic attraction between the tray components ensured stable and reproducible tray positioning throughout the impression procedure, eliminating the need for operator-applied finger pressure and facilitating a pressure-free mucostatic impression of the residual ridge. RESULTS: The SMART technique enabled accurate recording of the mandibular residual ridge anatomy without observable tissue displacement during impression making. The definitive impression produced a well-adapted master cast, resulting in a complete denture with satisfactory retention, stability, adaptation, and patient comfort during clinical evaluation. CONCLUSION: The SMART impression technique represents a simple, innovative, and clinically applicable approach for the prosthodontic management of mandibular knife-edge residual ridge. By eliminating manual tray stabilization and minimizing tissue displacement during impression making, it facilitates accurate mucostatic impressions and may improve denture fit, stability, and overall clinical performance. Further clinical studies involving larger patient populations are required to evaluate its reproducibility and long-term clinical effectiveness.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Verification Index for the Repositioning of a Single Implant Analog in the Correct Place: A Clinical Technical Case Report.Reports (MDPI) · 2026
- A Case Report of a Complete Removable Denture Designed to Restore Function in a Patient With Severe Resorption of the Mandibular Alveolar Ridge Using the Neutral Zone and Flange Techniques.Case reports in dentistry · 2026
- Prosthetic impression techniques for management of severely resorbed mandibular ridges: a systematic review.Evidence-based dentistry · 2026
- In Vivo Complete Arch Implant Impressions: Comparison of the Linear Precision of Digital and Conventional TechniquesInternational Dental Journal · 2026
- Effect of tray type and subsplint reinforcement on the trueness of complete arch implant impressions: An in vitro study.The Journal of prosthetic dentistry · 2026
- Additively Manufactured Zirconia Ceramic Cantilever Resin-Bonded Fixed Dental Prostheses With Customized Intaglio Microstructures for Replacing a Missing Lateral Incisor.Journal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.] · 2026