Biomaterial investigations in dentistry

Electrochemical corrosion properties of a novel sodium hyaluronate and zinc oxide nanoparticle-coated stainless steel orthodontic arch wire - an in-vitro study.

Najiya V Pallikkara, Shweta Nagesh, Pugalmani Sivashanmugam, Shantha Sundari

Department of Orthodontics, Saveetha Dental College and Hospitals, Saveetha Institute Of Medical And Technical Sciences, Saveetha University, Chennai, India. · Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India.

Key points

From the paper's conclusion
  • The ZnO-SH coating improved the corrosion resistance of SS orthodontic arch wires in the neutral and alkaline but not in the acidic environment.

Abstract

BACKGROUND: Nanoparticle-based surface modifications of orthodontic arch wires have been extensively investigated for antimicrobial and frictional properties. However, their effect on corrosion behaviour remains largely unexplored. OBJECTIVES: To evaluate the electrochemical corrosion resistance properties (corrosion potential [Ecorr], polarisation resistance [Rp], corrosion current density [icorr], corrosion rate [CR] and the impedance-derived charge-transfer resistance [Rct]) of zinc oxide and sodium hyaluronate (ZnO-SH)-coated and -uncoated stainless steel (SS) orthodontic arch wire in three simulated pH environments. MATERIALS AND METHODS: Thirty commercially available 19 × 25" SS arch wires were divided into coated (n = 15) and uncoated (n = 15) groups. The samples were immersed in neutral, acidic and alkaline pH at 37°C for 2 h. Electrochemical testing included potentiodynamic polarisation and electrochemical impedance spectroscopy (EIS). Statistical comparison was done using Welch's t-test and two-way Analysis of variance (ANOVA) with Bonferroni-corrected post-hoc comparisons. RESULTS: The effect of the ZnO-SH coating was strongly environment dependent, with a highly significant coating-to-environment interaction for all rate parameters (p < 0.001). In the neutral and alkaline environments, the coated wires showed significantly higher Rp and lower corrosion icorr and CR than the uncoated wires (p < 0.001). In the acidic medium, the opposite was observed: the uncoated wires had significantly higher Rp (822 vs. 91 kΩ·cm²) and significantly lower icorr (0.019 vs. 0.273 µA/cm²) than the coated wires (p < 0.001). Post-corrosion scanning electron microscopy confirmed an intact coating in the neutral and alkaline environments and extensive coating breakdown, pitting and cavitation in the acidic medium. CONCLUSION: The ZnO-SH coating improved the corrosion resistance of SS orthodontic arch wires in the neutral and alkaline but not in the acidic environment.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers