Need for removal of flexible intramedullary nails used to treat femoral shaft fractures in children: an observational study of 55 children with a minimum of 5-year follow-up.
Nicolas Robert Nietosvaara, Jussi Kosola, Yrjänä Nietosvaara, Jani Puhakka, Ilkka Helenius, Topi Laaksonen
Pediatric Orthopaedics and Traumatology, University of Helsinki and Helsinki New Children's Hospital, Helsinki, Finland; Department of Surgery, Päijät-Häme Central Hospital, Lahti, Finland. · Department of Orthopaedics and Traumatology, Helsinki University Hospital and University of Helsinki, Helsinki, Finland; Department of Orthopaedics and Traumatology, Kanta-Häme Central Hospital, Hämeenlinna, Finland.
Key points
From the paper's conclusion- Half of the children with unbent FIN placed flush to the bone in femoral shaft fractures had removal of nails. Extending the nail to or below the distal femoral growth plate leads to hardware removal in nearly all cases, mainly due to pain.
Abstract
BACKGROUND AND PURPOSE: Removal of flexible intramedullary nails (FIN) in children with femoral shaft fractures has been considered unnecessary when nails are left unbent flush to the bone. We aimed to evaluate the frequency and timing of nail removal on demand. METHODS: This is an observational follow-up study including consecutive 3-14-year-old children with femoral shaft fractures treated during 2011-2018 with FIN. The instruction was to leave the distal ends of the nails unbent above the distal femoral physis. Alignment of the fracture and position of the nails were assessed after nailing and during follow-up. Data on nail removal rates and timing was collected with at least 5 years of follow-up. The outcomes for children with correctly placed nails were compared with those with nails that were too long, defined as cut at or below the distal femoral physis evaluated from postoperative radiographs. RESULTS: 55 consecutive children were included. All fractures healed in satisfactory alignment. FINs were too long in 24 patients (20 distally, 4 proximally). Hardware was removed in 37 (67%) children at a median of 2.4 years from surgery because of pain (range 0.3-9.3). Removal occurred in 21/24 of those with too long nails, and in 16/31 patients with correctly applied FIN, RR 1.7 (95% confidence interval 1.2-2.5, P = 0.005). CONCLUSION: Half of the children with unbent FIN placed flush to the bone in femoral shaft fractures had removal of nails. Extending the nail to or below the distal femoral growth plate leads to hardware removal in nearly all cases, mainly due to pain.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Should we remove flexible intramedullary nails after diaphyseal forearm pediatric fracture? A cohort study of 288 patients.Acta orthopaedica · 2026
- Lateral-Only Flexible Intramedullary Nailing for Pediatric Tibial Shaft Fractures: An Early Comparative Experience With a Novel Technique to Reduce Symptomatic Implant Prominence.Journal of the Pediatric Orthopaedic Society of North America · 2026
- Prophylactic Intramedullary Nailing Following Femoral Lengthening in Congenital Femoral Deficiency: A Retrospective Comparative Study.Journal of clinical medicine · 2026
- Long-term implant retention after impacted elastic stable intramedullary nailing in pediatric diaphyseal forearm fractures: a retrospective cohort studyActa Orthopaedica · 2026
- Short-term Safety Profile of Trochanteric-Entry Intramedullary Lengthening Nails in Skeletally Immature Patients.Journal of the Pediatric Orthopaedic Society of North America · 2026
- Exploring physical recovery in children after intramedullary nailed femoral shaft fractures: a prospective pilot study.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026