Accuracy, Variability, and Bias of Glycemic Biomarkers in Patients Treated With Maintenance Dialysis
Leila R. Zelnick, Subbulaxmi Trikudanathan, Yoshio N. Hall, Ernest Ayers, Lisa Anderson, Nathaniel K. Ashford, EVELIN JONES, Andrea C. Rivas-Nieto,
Northwest Kidney Centers · University of Washington
Key points
From the paper's conclusion- HbA1c and GA may be useful assessments of average glycemia in patients treated with maintenance dialysis, if bias can be adequately addressed.
Abstract
OBJECTIVE: Accurate assessment of glycemia in patients treated with maintenance dialysis is imperative and hampered by known biases of glycated hemoglobin (HbA1c) in kidney failure (KF). This study evaluated the accuracy, variability, and covariate bias of three glycemic biomarkers compared with glycemia measured by continuous glucose monitor (CGM) among people with and without diabetes treated with maintenance dialysis. RESEARCH DESIGN AND METHODS: In a prospective community-based cohort study, 251 participants treated with maintenance dialysis wore a Dexcom G6 Pro CGM for 10 days. We compared correlations of HbA1c, glycated albumin (GA), and fructosamine with CGM-derived mean glycemia and examined sources of bias. RESULTS: Participants (43% women; 63% with diabetes) had a median of 9.3 (interquartile range 8.5-9.4) valid days of CGM data. Mean (SD) HbA1c, GA, fructosamine, and mean CGM glucose were 6.2% (1.4%), 19.6% (6.3%), 351 (99) µmol/L, and 170 (63) mg/dL, respectively. HbA1c, GA, and fructosamine all strongly correlated with mean CGM blood glucose, with HbA1c and GA more correlated than fructosamine (overall, r = 0.85, r = 0.87, and r = 0.70, respectively; in diabetes, r = 0.84, r = 0.84, and r = 0.64, respectively). Compared with mean CGM glucose, HbA1c was significantly biased by erythropoiesis-stimulating agent dose, BMI, hemoglobin, and serum albumin; GA and fructosamine were biased by dialysis modality and vintage, residual kidney function, and BMI. CONCLUSIONS: HbA1c and GA were strongly correlated with mean CGM blood glucose, but all biomarkers had substantial bias by relevant clinical characteristics. HbA1c and GA may be useful assessments of average glycemia in patients treated with maintenance dialysis, if bias can be adequately addressed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Correlation Between Glycemic Biomarkers and Continuous Glucose Monitoring Metrics in Chronic Kidney Disease: A Systematic Review and Correlation Meta-Analysis.Journal of clinical medicine · 2026
- Glycated albumin: An old yet new biomarker in people with diabetes and the potential for novel applications.Journal of diabetes investigation · 2026
- Beyond the glycation gap: A multicompartment framework for HbA1c-glycemia discordance in Pediatric type 1 diabetes.Clinica chimica acta; international journal of clinical chemistry · 2026
- Beyond HbA1c: Current and Emerging Glycation Biomarkers for Diabetes Diagnosis, Monitoring and Risk StratificationApplied Biosciences · 2026
- Association Between Short-Term Glycemic Variability Measured by Continuous Glucose Monitoring and Early Diabetic Kidney Disease in Type 2 Diabetes.Diabetes, metabolic syndrome and obesity : targets and therapy · 2026
- Glycemic biomarkers and cardiovascular disease in diabetes: a comparative analysis of population-based and clinical cohorts.Frontiers in endocrinology · 2026