INHALE-1: A Multicenter Randomized Trial of Inhaled Technosphere Insulin in Children With Type 1 Diabetes
Michael J. Haller, Lauren Kanapka, Roshanak Monzavi, Thomas J. Mouse, Gnanagurudasan Prakasam, Asheesh K. Dewan, Linda A. DiMeglio, Lori M. Laffel,
University of Florida · Jaeb Center for Health Research
Key points
From the paper's conclusion- However, TI use was safe over 26 weeks without affecting pulmonary function and was associated with greater treatment satisfaction and less weight gain compared with RAA, supporting TI as a treatment option for some pediatric patients with type 1 diabetes.
Abstract
OBJECTIVE: To evaluate inhaled technosphere insulin (TI) in children with diabetes. RESEARCH DESIGN AND METHODS: A total of 230 youth 4-17 years old with type 1 (98%) or type 2 (2%) diabetes treated with multiple daily injections of insulin were randomly assigned 1:1 to TI or rapid-acting analog (RAA) insulin plus continuation of long-acting basal insulin and continuous glucose monitoring (CGM) for 26 weeks. The primary outcome was change in HbA1c, tested for noninferiority with margin of 0.4%. RESULTS: In intent-to-treat analysis, mean HbA1c (% ± SD) was 8.22 ± 0.87 at baseline and 8.41 ± 1.38 at 26 weeks with TI and 8.21 ± 0.96 and 8.21 ± 1.10, respectively, with RAA (adjusted difference = 0.18; 95% CI -0.07, 0.43; noninferiority P = 0.091). CGM-measured time in range 70-180 mg/dL was not significantly different between groups (adjusted difference -2.2%; 95% CI -7.0, 2.7; P = 0.38). Two severe hypoglycemic events occurred in the TI group and one in the RAA group. Change in forced expiration volume in 1 s from baseline to 26 weeks did not differ comparing TI and RAA (P = 0.53). The TI group reported greater treatment satisfaction (P = 0.004) and had less gain in weight and BMI percentile (P = 0.009) than did the RAA group. CONCLUSIONS: The primary analysis did not meet the prespecified criteria for HbA1c noninferiority. However, TI use was safe over 26 weeks without affecting pulmonary function and was associated with greater treatment satisfaction and less weight gain compared with RAA, supporting TI as a treatment option for some pediatric patients with type 1 diabetes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Replacing or Supplementing Automated Insulin Delivery With Inhaled Insulin: A 90-Day Randomized Controlled TrialJournal of Diabetes Science and Technology · 2025
- Automated Insulin Delivery Use Among Preschool-Age Children With Type 1 Diabetes: A T1D Exchange Multicenter AnalysisJournal of Diabetes Science and Technology · 2026
- Technology choice, glycemic control and patient-reported outcome measures in adults with type 1 diabetes: A randomized crossover trial comparing a smart insulin pen with an automated insulin delivery system (EBIACE-1).Diabetes research and clinical practice · 2026
- Overcoming Therapeutic Inertia with Inhaled Insulin TherapyDiabetes Technology & Therapeutics · 2026
- Pulmonary Safety and Clinical Considerations for Inhaled Insulin: A Comprehensive ReviewDiabetes Technology & Therapeutics · 2026
- Expanding Patient Choice in Diabetes Care: Reducing Access Barriers to Inhaled Insulin.Diabetes technology & therapeutics · 2026