Initial Clinical Experience with Shape Memory Polymer Plugs for Various Venous Embolization.
Kaishu Tanaka, Yu Masuda, Hiroki Satomura, Kosuke Tomotake, Yuji Koretsune, Hiroki Yano, Shinya Kosai, Yasushi Kimura,
Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, Japan. · Department of Diagnostic Radiology, Ikeda Municipal Hospital, Japan.
Key points
From the paper's conclusion- Shape memory polymer plugs may be a feasible option in selected venous embolization cases. Their large occlusive volume, low radial force, and radiolucency offer procedural and imaging advantages. Device size limitations and anchoring requirements must be considered. Further studies and larger device options are needed.
Abstract
PURPOSE: Shape memory polymer plugs are novel, porous, self-expanding embolic devices that promote homogeneous thrombus formation with minimal imaging artifacts. Although increasingly used in arterial procedures, clinical data on venous applications remain limited. This technical note describes our initial experience with shape memory polymer plugs for multiple types of venous embolization and details the procedural techniques used to optimize outcomes. MATERIAL AND METHODS: Five patients underwent venous embolization using shape memory polymer plugs. Indications included a pelvic arteriovenous malformation outflow vein, pelvic congestion syndrome, gastric varices treated with balloon-occluded retrograde transvenous obliteration, and a congenital portosystemic shunt. Delivery systems included 5-F or 6-F guiding sheaths or a 9-F balloon catheter. Technical modifications included partial deployment, a 5-minute dwell time, anchoring using Amplatzer vascular plugs, temporary balloon protection, and adjunctive sclerosant administration. RESULTS: A total of 15 shape memory polymer plugs were deployed. Technical success was achieved in four of five cases. No plug migration occurred. One portosystemic shunt case showed persistent residual flow due to a size mismatch between the 12-mm shape memory polymer and the 10.5-mm vessel. Clinical improvement occurred in all patients. Follow-up (1-30 months) demonstrated durable occlusion in successful cases, confirmed by computed tomography with minimal artifact. CONCLUSIONS: Shape memory polymer plugs may be a feasible option in selected venous embolization cases. Their large occlusive volume, low radial force, and radiolucency offer procedural and imaging advantages. Device size limitations and anchoring requirements must be considered. Further studies and larger device options are needed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Early Results of Shape Memory Polymer Embolization for Endoleak Treatment after Thoracoabdominal Fenestrated/Branched Endovascular Aneurysm Repair.Annals of vascular surgery · 2026
- Clinical outcomes and midterm durability of the preloading coil-in-plug technique in various arterial territories.CVIR endovascular · 2026
- Pelvic Vein Embolization using different Embolic Agents for the Treatment of Pelvic Venous Insufficiency: A Systematic Review and Meta-Analysis.Journal of vascular surgery. Venous and lymphatic disorders · 2026
- Feasibility, safety, and efficacy of the amber peripheral liquid embolic system: results from stage I of the first-in-human OPAL study.CVIR endovascular · 2026
- Plug-Anchored Coil Embolization of a Paravalvular Aortic Pseudoaneurysm After TAVR With BASILICA.JACC. Case reports · 2026
- Advances in Design and Preparation of Biodegradable Inferior Vena Cava Filters.Materials (Basel, Switzerland) · 2026