科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ Journal of imaging informatics in medicine2026-09-15

Statistically Rigorous and Interpretable Radiomics for Benign-Malignant Classification on the BUSI-WHU Breast Ultrasound Dataset.

Prayas Sur Antu, Md Mahbub-Ur Rashid, Md Hazrat Ali

原始摘要(英文原文)· Original abstract
Radiomics has shown promise for breast ultrasound lesion classification, yet reported performance is often affected by patient-level leakage, feature selection bias, dependence between lesions from the same patient, and image formats lacking pixel-spacing metadata. The BUSI-WHU dataset allows these issues to be addressed together. We analyzed 927 breast lesions from 816 patients using 939 handcrafted radiomic features from expert-annotated images. Pixel spacing was recovered from dataset-supplied scale factors and images resampled to a common isotropic resolution. Features were assessed by Mann-Whitney U tests with Benjamini-Hochberg correction and Cliff's delta, with a one-lesion-per-patient sensitivity analysis. Six classifiers, including a penalized logistic regression baseline, were evaluated under ten-fold patient-grouped, class-stratified cross-validation with correlation filtering and Boruta selection inside each training fold. Confidence intervals and paired comparisons used patient-level bootstrap of out-of-fold predictions, and SHAP was computed on held-out patients. Of the 939 features, 587 differed significantly after correction; most remained significant under one-lesion-per-patient sampling; and 48 were selected consistently across folds. Pooled out-of-fold ROC-AUCs ranged from 0.828 to 0.834; no pairwise difference survived correction, and the logistic regression performed comparably to the best ensemble. Discrimination was unchanged when absolute size features were removed. Calibration did not follow discrimination: the two highest-ranked models were systematically overconfident, whereas the random forest was well calibrated despite equivalent discrimination. SHAP attributions were dominated by filtered texture. Radiomic features gave moderate discrimination under calibrated, leakage-resistant, patient-clustered evaluation. Classifier differences were minimal, no ensemble improved on a transparent linear model, and predicted probabilities would need recalibration before use.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Statistically Rigorous and Interpretable Radiomics for Benign-Malignant Classification on the BUSI-WHU Breast Ultrasound Dataset. — 科研速览 Science Skim