A developed recombinant antigen and monoclonal antibody based solid phase competitive ELISA for detection of foot and mouth disease virus serotype O specific antibodies.

S Mallick, R P Singh, J K Biswal, J K Mohapatra, M Rout, S K Kabi, R Ranjan

ICAR-National Institute on Foot and Mouth Disease, Arugul, Bhubaneswar-752050, Odisha, India. · MSc in Biotechnology, ICAR-National Institute on Foot and Mouth Disease, Arugul, Bhubaneswar-752050, Odisha, India.

Key points

From the paper's conclusion
  • The developed rP1-MAb-SPCE has the potential to facilitate the detection of antibodies against FMDV serotype O while mitigating biosecurity concerns. However, further validation involving a larger serum cohort is essential to confirm the assay's robustness.

Abstract

BACKGROUND: Foot and mouth disease (FMD) is ahighly contagious and economically burdensome viral disease of cloven-hoofed animals. Out of the seven FMD virus (FMDV) serotypes, type O is one of the most prevalent serotype in several parts of the world. AIMS: This study aimed to develop a recombinant capsid polyprotein (rP1) and monoclonal antibody (MAb)-based solid phase competitive ELISA (rP1-MAb-SPCE) to detect anti-FMDV/O antibodies in serum samples. METHODS: For the development of rP1-MAb-SPCE the concentrations of rP1, MAb and dilution of serum were optimized. Percent inhibition (PI) cut-off was determined based on ROC curve analysis of cattle sera (n=53) of known FMD vaccination status with reference to the gold standard virus neutralization test (VNT). The assay performance was further validated in comparison to the conventional polyclonal antibody (PAb)-based SPCE using FMDV-positive and negative serum samples (n=612) obtained from multiple species (cattle, goat, pig, fallow deer, antelope, giraffe and African buffalo). RESULTS: At the selected cut-off value of 30.77 PI, the rP1-MAb-SPCE exhibited 86.21% diagnostic sensitivity and 95.83% diagnostic specificity. A significant correlation (r=0.84; P<0.0001) was observed between the PI values of sera tested by rP1-MAb-SPCE and PAb-based SPCE and also the limits of detection of both of the assays were comparable. Repeatability tests demonstrated that the coefficients of variation within and between runs were <10% and <14%, respectively. CONCLUSION: The developed rP1-MAb-SPCE has the potential to facilitate the detection of antibodies against FMDV serotype O while mitigating biosecurity concerns. However, further validation involving a larger serum cohort is essential to confirm the assay's robustness.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers