From the paper's conclusion- FOT effectively detected improvements in pulmonary function following adenotonsillectomy and may be a valuable tool for evaluating respiratory changes in patients with ATH. Larger studies are warranted to better define its clinical utility.
Abstract
INTRODUCTION: Adenotonsillar hypertrophy (ATH) is a common cause of upper airway obstruction in the paediatric population, resulting in sleep disturbances, chronic airway obstruction, and potential cardiopulmonary complications. The Forced Oscillation Technique (FOT) is a sensitive, non-invasive method for assessing pulmonary function and detecting abnormalities of the peripheral airways. MATERIALS AND METHODS: This prospective pre-post cohort study included 35 patients aged 5-20 years with ATH who underwent FOT assessment before and six weeks after adenotonsillectomy. The parameters evaluated included total airway resistance (R5), central airway resistance (R20), peripheral airway resistance (R5-R20), reactance (X5), area of reactance (Ax), and resonant frequency (Fres). RESULTS: Significant postoperative improvements were observed in R5 (0.46±0.25 to 0.41±0.25 kPa/L/s; p = 0.001), R20 (0.35±0.19 to 0.30±0.18 kPa/L/s; p = 0.001), X5 (-0.24±0.16 to -0.12±0.13 kPa/L/s; p < 0.001), Ax (2.93±2.30 to 2.08±1.71 kPa/L/s; p < 0.001), and Fres (24.89±6.75 to 22.30±6.00 Hz; p < 0.001). Although R5-R20 improved (0.10±0.10 to 0.09±0.10 kPa/L/s), the change was not statistically significant (p = 0.427). As R5-R20, X5, and Ax reflect peripheral airway function, improvements in these parameters suggest enhanced peripheral airway function following adenotonsillectomy. No significant association was found between pulmonary function and the degree of adenoid or tonsillar hypertrophy. CONCLUSION: FOT effectively detected improvements in pulmonary function following adenotonsillectomy and may be a valuable tool for evaluating respiratory changes in patients with ATH. Larger studies are warranted to better define its clinical utility.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Electrocardiographic Changes Following Pediatric Adenotonsillectomy for Obstructive Sleep-Disordered Breathing: A Pilot Prospective Study.Pediatric reports · 2026
- P142. First-Night Polysomnography Shows Disrupted Sleep Despite Improved Obstruction After AdenotonsillectomySLEEP advances · 2026
- Application of numerical simulation of upper airway flow field in pediatric obstructive sleep apnea with adenoid hypertrophy.Quantitative imaging in medicine and surgery · 2026
- Time-Dependent Changes in Pulmonary Artery Pressure and Biventricular Function After Adenotonsillar Surgery: A Tissue Doppler Echocardiography Study.Echocardiography (Mount Kisco, N.Y.) · 2026
- P057. Respiratory complications in children with extremely severe OSA after adenotonsillectomySLEEP advances · 2026
- Right Ventricular Function and Pulmonary Arterial Coupling in Paediatric Obstructive Sleep Apnea.Echocardiography (Mount Kisco, N.Y.) · 2026