Electroencephalography (EEG) and Quantitative EEG for Acute Stroke Triage and Post-Reperfusion Monitoring: A Systematic Review.
Shirwan Hamasalih Omer, Sivan Jabbar Alimohammed, Mohammed Ibrahim Mohialdeen Gubari
Department of Basic Medical Sciences, College of Medicine, University of Sulaimani, Sulaymaniyah, Iraq. · Clinical Neurophysiology, Iraqi Board of Medical Specializations, Erbil Teaching Hospital, Ministry of Health Kurdistan Region, Iraq.
Key points
From the paper's conclusion- EEG/QEEG is a promising but still investigational adjunct for acute ischemic stroke triage and post-reperfusion monitoring. Current evidence does not support a universal diagnostic threshold, pooled diagnostic accuracy estimate, or stand-alone clinical implementation. Larger intended-use validation studies with complete diagnostic accuracy reporting and externally validated thresholds are required.
Abstract
INTRODUCTION: Electroencephalography and quantitative EEG are candidate functional biomarkers that may complement clinical examination and imaging for acute ischemic stroke triage and post-reperfusion monitoring. This review aimed to evaluate the value of electroencephalography (EEG) and quantitative EEG (QEEG) for acute stroke triage and post-reperfusion monitoring. METHODS: A systematic search was performed in PubMed, Embase, Scopus, and Web of Science on 4 February 2026, with supplementary backward and forward citation tracking. Eligible studies evaluated EEG, QEEG, processed EEG, visual EEG grading, or EEG-derived physiological markers for acute stroke/transient ischemic attack (TIA) classification, large-vessel occlusion (LVO)/medium-vessel occlusion (MeVO) detection, lesion-related classification, stroke control/severity classification, or post-endovascular treatment/mechanical thrombectomy (EVT/MT) monitoring. Diagnostic components were interpreted in line with Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) 2020 and PRISMA for diagnostic test accuracy (PRISMA-DTA) principles. Risk of bias was assessed using Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 for diagnostic/classification evidence and Quality in Prognostic Studies (QUIPS)-oriented criteria for post-EVT/MT monitoring studies. RESULTS: From 4,796 database records, 3,179 unique records were screened, 51 full texts were assessed, and 15 study records were retained: seven diagnostic/classification studies and eight post-EVT/MT monitoring studies. Acute triage evidence suggested candidate value for EEG/QEEG in acute stroke/TIA or LVO/MeVO identification, with promising individual-study signals for slow-to-fast ratios, hemispheric asymmetry/ pairwise-derived brain symmetry index (pdBSI), relative alpha/theta power, and clinical-plus-EEG models. However, devices, settings, target conditions, thresholds, and validation status varied, and no diagnostic domain was poolable. No diagnostic meta-analysis was performed because target conditions, thresholds, reference standards, EEG systems, and intended-use settings were too heterogeneous. Post-EVT/MT monitoring studies suggested candidate value for QEEG slowing/frontal delta alpha ratio (DAR), relative alpha loss, visual EEG grading, Non-Convulsive Status Epilepticus (NCSE) detection, bispectral index (BIS)/near-infrared spectroscopy (NIRS), and EEG-transcranial Doppler (TCD) neurovascular coupling (NVC) in relation to early neurological deterioration (END), edema, seizure-related complications, infarct growth, or functional outcome. Certainty was very low for diagnostic domains and low for post-EVT/MT monitoring. CONCLUSIONS: EEG/QEEG is a promising but still investigational adjunct for acute ischemic stroke triage and post-reperfusion monitoring. Current evidence does not support a universal diagnostic threshold, pooled diagnostic accuracy estimate, or stand-alone clinical implementation. Larger intended-use validation studies with complete diagnostic accuracy reporting and externally validated thresholds are required.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Quantitative EEG and EEG-Derived Markers of Severity, Prognosis, and Recovery After Ischemic Stroke: A Systematic Review.Archives of academic emergency medicine · 2026
- Lesion-directed quantitative EEG after reperfusion therapy is associated with malignant cerebral edema and functional outcomes in acute ischemic stroke: a prospective exploratory cohort study.Frontiers in neurology · 2026
- Critical Care Monitoring in Comatose Patients Receiving ECMO: A Cohort Study of Machine Learning on Quantitative EEG for Diagnosing Acute Brain Injury and Prognosticating Mortality.Journal of clinical medicine · 2026
- Quantitative Electroencephalography Correlates With Acute Neurologic Events in Extracorporeal Membrane Oxygenation: A Pediatric Case Series.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2026
- Early Frontal qEEG Markers Predict Delayed Cognitive Recovery After Mild-to-Moderate Ischemic Stroke: A Prospective Cohort Study.Clinical EEG and neuroscience · 2026
- Quantitative EEG-Based Detection of Poststroke Delirium Endotypes and Their Association With Biomarkers of Inflammation.Brain and behavior · 2026