  • Reporting reactivity in EMA appears protocol-dependent. The coverage-based protocol was associated with modest reporting reactivity, which challenges the common assumption of reporting invariance in EMA and underscores the importance of considering protocol design when interpreting within-person change.

Abstract

BACKGROUND: A central concern in ecological momentary assessment (EMA) research is whether repeated self-report alters the reporting process itself. In most EMA domains, longitudinal stability of reporting is assumed but rarely tested. OBJECTIVE: This study leveraged concurrent accelerometry as a temporal anchor to evaluate (1) whether self-reported physical activity (PA) and sedentary behavior (SB) exhibited temporal shifts across a 7-day monitoring period and (2) whether this temporal shift differed across near-momentary (5-min reporting period) and coverage-based (120-min recall period) EMA protocols. METHODS: We conducted a secondary analysis of 315 US adults recruited from the Understanding America Study panel between January and July 2023 for the current study. Participants were monitored in their natural environments for 7 days via 2 measurement methods: continuous thigh-worn activPAL4 accelerometry and 5 daily smartphone EMA prompts assessing PA and SB. Reporting reactivity was defined as divergence in the temporal trajectories of EMA-reported behavior relative to accelerometry. Multilevel models with random intercepts and slopes tested whether linear and quadratic study day effects differed across the 2 methods (method × study day interactions). Protocol differences were examined using multivariable method × protocol × study day interactions, comparing coverage-based and near-momentary EMA designs. RESULTS: In the coverage-based protocol, EMA-reported PA and SB exhibited temporal trajectories that diverged significantly from concurrent accelerometry (SB linear divergence: b=1.40, 95% CI 0.20-2.61, P=.02; PA linear divergence: b=-1.91, 95% CI -2.93 to -0.90, P<.001; and PA quadratic divergence: b=0.28, 95% CI 0.12-0.44, P<.001). No evidence of such divergence was found in the near-momentary protocol. The divergence in reporting trajectories differed significantly between the 2 protocols (SB linear 3-way interaction: b=-2.58, P=.02; PA linear 3-way interaction: b=1.86, P=.04). CONCLUSIONS: Reporting reactivity in EMA appears protocol-dependent. The coverage-based protocol was associated with modest reporting reactivity, which challenges the common assumption of reporting invariance in EMA and underscores the importance of considering protocol design when interpreting within-person change.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Temporal Stability of Repeated Self-Reported vs Device-Measured Behavior: Observational Study Using Ecological Momentary Assessment — Science Skim