Interpretable Recalibration of a Sequential Organ Failure Assessment-Derived Score Using Machine Learning-Guided Optimization: Multicenter Cohort Study.
Juan Dueñas-Ruiz, Yanelis Manzano Nieves, Anny María Hernández Cuello, Jaime Azpiazu Saiz, Ancor Sanz-García, Agustín Mayo-Íscar, Francisco Martín-Rodríguez, Isabel de la Torre
Faculty of Medicine, Universidad de Valladolid, Avda. Ramón y Cajal, 7, Valladolid, 47005, Spain, +34 983 42 30 00. · European University of the Atlantic, Santander, Spain.
Key points
From the paper's conclusion- Data-driven recalibration under explicit structural constraints can update the cutpoints and integer weights of an established clinical score without abandoning its additive, bedside-computable form and should transfer to other legacy instruments. The recalibrated score is a mortality risk model on its own 0-71 scale; an open-source calculator is provided, and external and prospective validation is required before clinical use.
Abstract
BACKGROUND: The Sequential Organ Failure Assessment (SOFA) score is central to risk stratification in intensive care units (ICUs), but its thresholds and 0- to 4-point increments were set by expert consensus in 1996 and never reestimated from outcome data. Machine learning models discriminate better while discarding the additive, point-based structure that makes SOFA auditable at the bedside, and methods for updating a legacy score rather than replacing it remain scarce. OBJECTIVE: This study aimed to develop and internally validate a data-driven recalibration of a SOFA-derived score that learns thresholds and integer weights from outcome data while preserving an additive, interpretable point-based structure and to test whether it improves discrimination for ICU mortality over a prespecified SOFA-derived reference score. METHODS: We conducted a retrospective multicenter cohort study using the eICU Collaborative Research Database (208 US hospitals, 2014-2015). We analyzed 14,848 adult first ICU admissions with complete day 1 SOFA-related measurements; 133,684 (90%) of 148,532 encounters with outcome data were excluded because of at least 1 missing determination. As vasoactive dose units could not be harmonized and urine output was largely unavailable, a prespecified SOFA-derived reference score served as the comparator. The framework couples supervised discretization (univariate decision trees and interval number chosen by a penalized validation criterion) with constrained integer-weight optimization under monotonicity, integrality, and scale-anchoring constraints, plus logistic calibration. Performance was estimated from pooled out-of-fold predictions of 10-fold nested cross-validation grouped by hospital, with bootstrap CIs; final thresholds and weights were refit on the full cohort and contributed no performance estimate. RESULTS: ICU mortality was 17.03% (2529/14,848). The recalibrated score achieved an area under the receiver operating characteristic curve (AUROC) of 0.811 (95% CI 0.800-0.819) versus 0.751 (95% CI 0.740-0.761) for the reference score (paired difference 0.059, 95% CI 0.053-0.067), and an area under the precision-recall curve of 0.495 (95% CI 0.477-0.515) versus 0.393 (95% CI 0.377-0.411; paired difference 0.102, 95% CI 0.087-0.116). Improvement was consistent across all 10 hospital-grouped folds and length-of-stay strata. After unweighted logistic recalibration, global calibration was adequate; the Brier score was lower (0.112 vs 0.123), whereas other calibration-error measures were higher. Discrimination approached unconstrained XGBoost (Extreme Gradient Boosting; AUROC 0.818) and exceeded penalized logistic regression (AUROC 0.775) fitted on the same folds. The advantage persisted in all 1000 resampling replications and in a prespecified sensitivity analysis expanding the cohort to 61,469 encounters (median paired AUROC difference 0.037). CONCLUSIONS: Data-driven recalibration under explicit structural constraints can update the cutpoints and integer weights of an established clinical score without abandoning its additive, bedside-computable form and should transfer to other legacy instruments. The recalibrated score is a mortality risk model on its own 0-71 scale; an open-source calculator is provided, and external and prospective validation is required before clinical use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Does Replacing SOFA-1 with SOFA-2 Change Mortality Discrimination and Calibration Across Patient Subgroups? A Paired Analysis in MIMIC-IVmedRxiv · 2026
- Predictive validity of daily sequential organ failure assessment (SOFA)-2 score for 30-day mortalityCritical Care · 2026
- Integrating dynamic SOFA changes and age to predict 28-day mortality in ICU patients: a nomogram and machine learning validation studyFrontiers in Medicine · 2026
- Evaluation of Sequential Organ Failure Assessment-2 Performance Across Demographic Subgroups: An External Validation Using MIMIC-IVCritical Care Medicine · 2026
- Development and Validation of the Sequential Organ Failure Assessment (SOFA)-2 ScoreJAMA · 2025
- Association Between the Sequential Organ Failure Assessment-2 (SOFA-2) Score and 90-Day and 365-Day Mortality in Patients With Sepsis: A Retrospective Cohort Study Based on the MIMIC-IV Database.Shock (Augusta, Ga.) · 2026