Journal of medical Internet research

Safety-Oriented Benchmarking of Large Language Models in Risk-Based Management of Abnormal Cervical Screening Results: Scenario-Based Benchmark Study.

Ömer Osman Eroğlu, Cansın Eroğlu

Department of Obstetrics and Gynecology, Ankara Etlik City Hospital, Ankara, Türkiye.

Computational

Key points

From the paper's conclusion
  • Safety-oriented benchmark performance in initial ASCCP risk-based management varied markedly by model, prompt condition, and scenario complexity. The guideline-directed prompt package was associated with improvement in both safety and guideline concordance, but even the best-performing model remained vulnerable in complex, history-dependent scenarios. LLMs may have value as clinician-supervised decision support tools, but these benchmark findings should not be interpreted as supporting autonomous clinical use in cervical screening management.

Abstract

BACKGROUND: Large language models (LLMs) are increasingly being considered for clinical decision support, yet their safety in risk-based cervical screening management remains insufficiently characterized. OBJECTIVE: This study benchmarked the guideline concordance and safety-related performance of 3 LLMs in the initial American Society for Colposcopy and Cervical Pathology (ASCCP) risk-based management of abnormal cervical screening results, using a purposively constructed synthetic scenario set that oversamples complex and history-dependent decision nodes. METHODS: We developed 60 synthetic clinical scenarios reflecting initial abnormal screening management in immunocompetent, nonpregnant women aged 25 to 65 years using a predefined scenario coverage matrix. GPT-5.3, Gemini 3 Flash, and DeepSeek V3.2 were tested under 2 prompt conditions: Baseline Clinical Prompt and Guideline-Directed Prompt Package. Each scenario was run in 3 independent repetitions per model and prompt arm (1080 total observations). Responses were evaluated by 2 obstetrics and gynecology specialists, blinded to model and prompt-arm identity but not independent of gold-standard construction, using a prespecified rubric. The primary end point was the unsafe major error-free rate. Proportions are reported with CIs adjusted for within-scenario clustering, and generalized estimating equations were used for inferential comparisons. RESULTS: Under the guideline-directed prompt package, the unsafe major error-free rate was 100% (95% CI 94%-100%) for GPT-5.3, 98.9% (95% CI 94%-99.8%) for Gemini 3 Flash, and 75% (95% CI 63.2%-84%) for DeepSeek V3.2. In the main-effects model, the guideline-directed prompt package was associated with higher odds of both unsafe major error-free performance (odds ratio [OR] 3.76, 95% CI 2.45-5.77; P<.001) and exact concordance (OR 8.27, 95% CI 4.14-16.52; P<.001). Error rates increased substantially with scenario complexity, rising from 3.1% in low-complexity to 29% in high-complexity scenarios. The most frequent error subtypes were undermanagement, genotype misinterpretation, and history neglect. Interrater agreement was almost perfect (weighted κ=0.839, 95% CI 0.811-0.867). CONCLUSIONS: Safety-oriented benchmark performance in initial ASCCP risk-based management varied markedly by model, prompt condition, and scenario complexity. The guideline-directed prompt package was associated with improvement in both safety and guideline concordance, but even the best-performing model remained vulnerable in complex, history-dependent scenarios. LLMs may have value as clinician-supervised decision support tools, but these benchmark findings should not be interpreted as supporting autonomous clinical use in cervical screening management.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Safety-Oriented Benchmarking of Large Language Models in Risk-Based Management of Abnormal Cervical Screening Results: Scenario-Based Benchmark Study — Science Skim