Evaluating a Guideline-Integrated Clinical Interaction Framework Vs a Standard Large Language Model Interaction for Dietary Recommendations in Recurrent Urolithiasis: In Silico Study.
Xiaofeng Wang, Jun Li, Yudong Hu, Yujie Chen, Yong Zhong, Faming Zhu, Ye Yuan, Fan Yang,
Department of Urology, The Thirteenth People's Hospital, No. 16, Railway New Village, Huangjueping Subdistrict, Jiulongpo District, Chongqing, China, 86 15808005558.
Key points
From the paper's conclusion- In this in silico study, a guideline-integrated, safety-aware clinical interaction framework generated higher-quality dietary recommendations for recurrent urolithiasis than a standard LLM condition with structured vignette inputs. This advantage was retained with patient query-style inputs. These findings suggest that explicit clinical framing, guideline grounding, and safety-oriented response scaffolding may improve the reliability of specialty counseling tasks involving metabolic stone prevention. Further validation is needed using real patient-authored queries and prospective clinical workflows.
Abstract
BACKGROUND: Personalized dietary counseling is central to recurrence prevention in patients with urolithiasis, particularly after a 24-hour urine metabolic evaluation. However, translating quantitative metabolic abnormalities into patient-facing, guideline-concordant, and safe dietary recommendations can be challenging in routine clinical practice. Large language models (LLMs) may assist with this task, but unguided responses may overlook key metabolic priorities or case-specific safety constraints. OBJECTIVE: This study evaluated whether a guideline-integrated, safety-aware, LLM-based clinical interaction framework (StoneAgent) could generate higher-quality, personalized dietary recommendations than a standard LLM configuration for recurrent urolithiasis. We also assessed whether any performance advantage persisted when the same clinical scenarios were presented as patient query-style inputs. METHODS: We conducted an in silico comparative study using 30 synthetic clinical vignettes representing common, mixed, and safety-relevant metabolic stone scenarios. For the primary experiment, StoneAgent and a standard LLM configuration were compared using structured vignette inputs. For the robustness experiment, each vignette was reformulated into 2 patient query-style variants (query A and query B), preserving the same clinical content in more natural conversational language. A vignette-specific expert reference standard was developed from guideline-informed specialist consensus. Three independent reviewers blindly rated outputs on a 5-point Likert scale for metabolic specificity, guideline adherence, and actionability; safety was assessed as a binary outcome. For the patient query-style experiment, query A and query B were aggregated at the vignette level for paired comparison. RESULTS: In the structured-input experiment, StoneAgent achieved higher performance than the standard LLM across metabolic specificity, guideline adherence, and actionability, with median case-level scores of 5.00 (IQR 5.00-5.00) vs 3.00 (IQR 2.75-3.92) for metabolic specificity, 5.00 (IQR 5.00-5.00) vs 3.67 (IQR 3.08-4.00) for guideline adherence, and 5.00 (IQR 5.00-5.00) vs 3.00 (IQR 2.67-3.33) for actionability (all P<.001). Safety pass rates were 100% (30/30) for StoneAgent and 83.3% (25/30) for the standard LLM (exact McNemar P=.06). In the patient query-style robustness experiment, StoneAgent retained a directional advantage after case-level aggregation, with mean scores of 4.44 vs 3.62 for metabolic specificity, 4.51 vs 3.63 for guideline adherence, and 4.11 vs 3.40 for actionability. Safety pass rates were 100% (30/30) for StoneAgent and 90% (27/30) for the standard LLM (exact McNemar P=.25). The performance gap was more conservative under patient query-style inputs compared with structured inputs, but the overall pattern remained consistent across domains. CONCLUSIONS: In this in silico study, a guideline-integrated, safety-aware clinical interaction framework generated higher-quality dietary recommendations for recurrent urolithiasis than a standard LLM condition with structured vignette inputs. This advantage was retained with patient query-style inputs. These findings suggest that explicit clinical framing, guideline grounding, and safety-oriented response scaffolding may improve the reliability of specialty counseling tasks involving metabolic stone prevention. Further validation is needed using real patient-authored queries and prospective clinical workflows.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Assessing the Limitations of Large Language Models in Clinical Practice Guideline–Concordant Treatment Decision-Making on Real-World Data: Retrospective StudyJMIRx Med · 2025
- Evaluation of large language models for clinical decision support in prostate cancer: a multidisciplinary Delphi study.Journal of comparative effectiveness research · 2026
- Evaluation of large language models for clinical decision support in renal cell carcinoma: a multidisciplinary Delphi study.Journal of comparative effectiveness research · 2026
- Evaluation of large language models for guideline-based clinical questions in muscle-invasive and non-muscle-invasive bladder cancer and upper tract urothelial carcinoma: a multidisciplinary Delphi study.Journal of comparative effectiveness research · 2026
- Enhancing clinicians’ trust in large language models via transparent source attribution: A randomized controlled evaluation in uro-oncologyEuropean Journal of Cancer · 2025
- Guideline adherence and expert-rated potential safety concerns in AI-generated dietary advice for patients with cirrhosis: a comparative evaluation of large language models.Frontiers in nutrition · 2026