JMIR medical education

Accuracy of Left Ventricular Ejection Fraction Assessment by Noncardiologists E-Point Septal Separation and Teichholz Methods: Simulation-Based Pre-Post Training Study.

Thanat Tangpaisarn, Nattapat Serewiwattana, Praew Kotruchin, Patpitchaya Siritanont, Noor Hafizah Abdul Salim, Pariwat Phungoen

Department of Emergency Medicine, Faculty of Medicine, Khon Kaen University, Khon Kaen, Khon Kaen, Thailand. · Queen Sirikit Heart Center of the Northeast, Faculty of Medicine, Khon Kaen University, Khon Kaen, Khon Kaen, Thailand.

Computational · n=26

Key points

From the paper's conclusion
  • Following focused ultrasound training, no statistically significant difference in absolute LVEF error was detected among methods in the preserved-LVEF assessment or in the SP with an LVEF of 48%. However, EPSS demonstrated greater error than both Teichholz methods in the single SP with an LVEF of 16%, a case-specific finding that should be considered hypothesis-generating. EPSS required less time to perform and was associated with higher learner confidence.

Abstract

BACKGROUND: Point-of-care ultrasound (POCUS) enables rapid bedside estimation of left ventricular ejection fraction (LVEF) in the emergency department. Among quantitative methods, E-point septal separation (EPSS) and Teichholz-derived calculations are commonly used; however, their comparative accuracy when performed by noncardiologist clinicians remains unclear. OBJECTIVE: This study aimed to compare the accuracy and efficiency of EPSS and Teichholz-based methods for LVEF assessment by emergency department physicians, using the Simpson biplane method as the reference standard. METHODS: We conducted a prospective pre-post interventional study using standardized patients (SPs) at a university simulation training unit (March 2025). Following prerecorded lectures and demonstration videos, emergency department physicians (n=26) measured LVEF using three bedside methods-EPSS, Teichholz long-axis, and Teichholz short-axis-before and after a focused hands-on training session including supervised image acquisition and guided LVEF measurement. Five SPs with cardiologist-confirmed LVEF values ranging from 16% to 73% were used across the study assessments. The primary outcome was the absolute difference between participant-measured and reference LVEF. Secondary outcomes included time-to-completion and participant-reported confidence for each method. RESULTS: Before training, EPSS demonstrated a significantly lower absolute error (median 5 percentage points, IQR 3-13) compared with Teichholz long-axis (17 percentage points, IQR 9-27) and Teichholz short-axis (13 percentage points, IQR 4-24) methods (P=.009). EPSS also required less time (median 73 seconds, IQR 53-121) than Teichholz long-axis (150 seconds, IQR 103-200) and Teichholz short-axis (100 seconds, IQR 67-184) (P=.02). After training, no statistically significant difference in absolute LVEF error was detected among methods in the preserved-LVEF assessment (P=.93). In the posttraining reduced-LVEF assessment, no statistically significant difference in absolute LVEF error was detected among methods in the SP with an LVEF of 48% (P=.48). In contrast, in the single SP with an LVEF of 16%, absolute LVEF error differed significantly among methods (P=.008), with greater error for EPSS (median 30.5 percentage points) than for Teichholz long-axis (11 percentage points) and Teichholz short-axis (8 percentage points). EPSS remained the fastest technique in preserved (62 seconds; P<.001) and reduced LVEF cases (79 seconds; P<.001). Confidence scores improved across all methods, with EPSS demonstrating the highest median posttraining confidence (P=.01). Greater variability in EPSS measurements was observed in reduced LVEF, with a mean bias of -16 (SD 23) percentage points and wide 95% limits of agreement from -61.1 to 29.1. CONCLUSIONS: Following focused ultrasound training, no statistically significant difference in absolute LVEF error was detected among methods in the preserved-LVEF assessment or in the SP with an LVEF of 48%. However, EPSS demonstrated greater error than both Teichholz methods in the single SP with an LVEF of 16%, a case-specific finding that should be considered hypothesis-generating. EPSS required less time to perform and was associated with higher learner confidence. TRIAL REGISTRATION: Thai Clinical Trials Registry TCTR20250123008; https://tinyurl.com/3kphcru3.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers