Estimating the Charlson Comorbidity Index From Privacy-Truncated Diagnosis Codes: Single-Center Retrospective Cohort Study Evaluating Five Computational Strategies in 507,949 Inpatient Encounters.
Gaetan Kamdje Wabo, Piotr Pawel Sokolowski, Mahboubeh Jannesari Ladani, Nandhini Santhanam, Michael Hagmann, Thomas Ganslandt, Fabian Siegel
Department of Biomedical Informatics at the Mannheim Institute for Intelligent Systems in Medicine (MIISM), Medical Faculty of Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, Building 3, Level 4, Mannheim, Baden-Württemberg, 68167, Germany, 49 621 383 8088. · Institute of Medical Informatics, Biometry and Epidemiology, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Bavaria, Germany.
Key points
From the paper's conclusion- In this single-center cohort, frequency-informed estimation reconstructed the CCI from three-character codes with an MAE of about 0.14 points. Expected-value estimation (S2) is the most parsimonious choice for encounter-level accuracy. The integer-valued median (S4) can suit analyses that depend on the score distribution. Use in clinical research remains a potential application that requires multisite validation.
Abstract
BACKGROUND: The Charlson Comorbidity Index (CCI) is a standard instrument for risk adjustment in the secondary use of clinical data. Its coding algorithms require International Classification of Diseases, Tenth Revision(ICD-10) codes with at least 4 characters. Hospital data integration centers may truncate codes to 3 characters for privacy. Truncation makes subcodes ambiguous across Charlson groups and can render the CCI noncomputable. OBJECTIVE: The primary objective was to develop, openly release, and evaluate computational strategies that estimate the CCI from 3-character International Statistical Classification of Diseases, Tenth Revision, German Modification (ICD-10-GM) codes using national 4-character subcode frequencies from the German Federal Statistical Office (Destatis). The secondary objective was to identify and quantify potential error caused by truncation and error induced by the national prior. METHODS: This single-center retrospective cohort study analyzed 507,949 inpatient encounters of 243,677 patients from University Hospital Mannheim (UMM; 2010-2024). The open-source R (The R Foundation) package miCCI (version 1.0.0; developed by Gaetan Kamdje Wabo et al.) implements a deterministic interval estimator (S1), an exact expected-value estimator (S2), multiple imputation (S3), a Dirichlet-smoothed predictive median (S4), and a cross-validated Meta Learner. Age-conditioned priors came from Destatis table 23131-01. The reference standard was the Quan-weighted CCI computed from full-length codes. We report mean absolute error (MAE), root mean square error (RMSE), Bland-Altman limits, Kolmogorov-Smirnov (KS) distance, and exact agreement with patient-level cluster bootstrap 95% CIs. Robustness analyses covered hyperparameters, a local oracle prior, prefixes without Destatis subcodes, Bonferroni-corrected subgroups, and nested cross-validation. RESULTS: S2, S3, and S4 achieved nearly identical MAE. S2 reached 0.1394 (95% CI 0.1379-0.1408), S3 reached 0.1395 (95% CI 0.1380-0.1408), and S4 reached 0.1390 (95% CI 0.1374-0.1405). All 3 were more accurate than S1 (MAE 0.1678, 95% CI 0.1660-0.1695) and the Meta Learner (MAE 0.1451, 95% CI 0.1437-0.1465). S2 computes exactly the expected score that S3 approximates by sampling, which explains their near-identical errors. S4 preserved the reference distribution best (KS distance 0.023, exact agreement 87.0%). The Meta Learner attained the lowest squared error (RMSE 0.318), also under nested cross-validation. In paired testing within a random subsample of 10,000 patients, S4 at its default setting did not differ from the best S3 setting. Under an in-sample oracle prior, 73% to 90% of the MAE of S2 to S4 remained, and prior mismatch accounted for the rest. After Bonferroni correction, 10 of 20 ICD-10 chapters retained a decisive best strategy. CONCLUSIONS: In this single-center cohort, frequency-informed estimation reconstructed the CCI from 3-character codes with an MAE of about 0.14 points (S2: 0.1394, 95% CI 0.1379-0.1408; S3: 0.1395, 95% CI 0.1380-0.1408; S4: 0.1390, 95% CI 0.1374-0.1405). Expected-value estimation (S2) is the most parsimonious choice for encounter-level accuracy. The integer-valued median (S4) can suit analyses that depend on the score distribution. Use in clinical research remains a potential application that requires multisite validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Developing Country-Specific Charlson Comorbidity Index Mappings for Use with German Administrative Data: Methodological Comparative Study.JMIR medical informatics · 2026
- medicalcoder: a unified and longitudinally aware framework for International Classification of Diseases code-based comorbidity assessment in R.JAMIA open · 2026
- Harnessing large language models for reliable automatic Charlson Comorbidity Index scoring: a validation study.JAMIA open · 2026
- A semantic-based carry-forward approach: Uncovering chronic disease burden in real-world data analysis.International journal of medical informatics · 2026
- Diagnostic Entropy as an Administrative Measure of Cross-System Diagnostic Dispersion in Noncommunicable Disease Inpatients: A Methodological Validation Study.Journal of nursing management · 2026
- External Validation and Adaptation of the Cambridge Multimorbidity Score Using German Claims Data.The American journal of managed care · 2026