Fine-Tuning, Retrieval-Augmented Generation, and Hybrid Adaptation of Language Models for Clinical Decision-Making in Health Care: Systematic Review.
Anshum Patel, Yugant Khand, Sai Krishna Vallamchetla, Pengze Li, Cui Tao, Joseph Cheung
Division of Pulmonary, Allergy and Sleep Medicine, Mayo Clinic, 4500 San Pablo Road South, Jacksonville, FL, United States, 1 904-953-2000. · Department of Neurology, Mayo Clinic in Florida, Jacksonville, FL, United States.
Key points
From the paper's conclusion- Adaptation strategies should align with task needs, using fine-tuning for narrow classification, RAG for guideline-grounded reasoning, and hybrid approaches for complex multimodal tasks. However, the evidence base remains largely retrospective or benchmark-based. Prospective studies with external validation, calibration, and standardized safety reporting are needed before broader clinical use.
Abstract
BACKGROUND: Large language models (LLMs) demonstrate strong performance on medical knowledge benchmarks, but their safe and effective use in clinical practice depends on posttraining adaptation rather than raw model capability. Fine-tuning, retrieval-augmented generation (RAG), and hybrid approaches are principal strategies for grounding language models in clinical evidence, yet their comparative effectiveness remains unclear. OBJECTIVE: This systematic review aims to synthesize evidence on fine-tuning, RAG, and hybrid posttraining strategies for clinical diagnosis and decision-support tasks and to identify strategy-task alignments and methodological features associated with improved performance. METHODS: We conducted a systematic review in accordance with PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) 2020 guidelines. PubMed/MEDLINE, Scopus, and Web of Science were searched from January 2018 through May 2026. Eligible studies evaluated transformer-based language models that underwent posttraining adaptation, retrieval augmentation, or both for clinical decision support, diagnosis, triage, risk stratification, or related health care applications. Studies evaluating nonadapted models, non-language-model AI systems, prompt engineering without performance evaluation, or nonclinical applications were excluded. Data extracted included model architecture, adaptation strategy, clinical domain, validation approach, and performance outcomes. Risk of bias was assessed using PROBAST+AI (Prediction model Risk of Bias Assessment Tool for AI). Studies were grouped according to the primary enhancement strategy (fine-tuning or parameter-efficient fine-tuning, RAG, or hybrid approaches), and findings were synthesized descriptively. RESULTS: Of 1890 identified records, 35 studies published between 2024 and 2026 met eligibility criteria. Enhancement strategies included RAG (17/35, 48.6%), fine-tuning or parameter-efficient fine-tuning (7/35, 20%), and hybrid approaches (11/35, 31.4%). Studies included diverse specialties from oncology, neurology, radiology, mental health, cardiology, ophthalmology, and surgical care. Fine-tuning demonstrated strong performance for task-specific applications, achieving area under the receiver operating characteristic curve values up to 0.912 for cancer detection and area under curve of 0.892 for major depressive disorder prediction, while matching clinician-level diagnostic performance in several studies. RAG improved guideline adherence and diagnostic accuracy, with increases from 71.1% to 92.1% and from 78.9% to 94.7% in guideline-based decision-support tasks. However, benefits were inconsistent across larger reasoning-capable models. Hybrid systems generally achieved the strongest performance in complex clinical workflows, with external validation accuracies exceeding 90% in stroke triage, dermatology, multimodal imaging, and oncology applications. Risk-of-bias assessment identified substantial methodological limitations, with 25 studies judged as high risk, 9 as unclear risk, and only 1 as low risk overall. Common concerns included inadequate external validation, lack of calibration assessment, nonrepresentative participant selection, and insufficient reporting of analytical methods. CONCLUSIONS: Adaptation strategies should align with task needs, using fine-tuning for narrow classification, RAG for guideline-grounded reasoning, and hybrid approaches for complex multimodal tasks. However, the evidence base remains largely retrospective or benchmark-based. Prospective studies with external validation, calibration, and standardized safety reporting are needed before broader clinical use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A survey on retrieval-augmentation generation (RAG) models for healthcare applicationsNeural Computing and Applications · 2025
- Generative large language models in medicine: a scoping review of recent methodological advances.npj health systems · 2026
- Effective prompt design for large language models in clinical practiceActa Clinica Belgica · 2026
- Retrieval-augmented generation in biomedicine: a survey of technologies, datasets, and clinical applicationsArtificial Intelligence Review · 2026
- A Self-Controlled Benchmark of Retrieval-Augmented Generation for Large Language Models on Clinical Guideline Questions.Diagnostics (Basel, Switzerland) · 2026