Key points
From the paper's conclusion- Powered STS assistance was feasible for most assisted transfers: 27 of 30 repetitions (90%) succeeded under the linear trajectory, which also produced the lowest mean perceived effort of the 3 conditions. The S-shape trajectory was more demanding, producing more partial completions and no effort reduction relative to the conventional rollator. In this first evaluation of SkyWalker with its intended users, the assistance profile, not powered assistance itself, is the variable to prioritize in further testing, and the results, which motivate trajectory personalization and brief familiarization, are informing the design of the next SkyWalker generation.
Abstract
BACKGROUND: Robotic mobility aids with sit-to-stand (STS) support may help older adults reduce physical effort during a demanding, fall-prone daily task. OBJECTIVE: This paper reports a feasibility evaluation of the "SkyWalker" robotic walker, which provides powered STS assistance via actuated lower handles. The 2 trajectories (linear and S-shape) were selected to examine how assistance profile shape influences feasibility, biomechanics, and user experience. METHODS: Seven older adult patients with mobility challenges were enrolled from a rehabilitation hospital. One withdrew during the robot familiarization (unable to stand up) without attempting any study trial, and 6 completers (4 women, 2 men; aged 70-84 years) form the analyzed sample. Participants completed 3 within-subject conditions: SkyWalker with the linear trajectory, SkyWalker with the S-shape trajectory, and a conventional rollator. We quantified STS task performance, perceived exertion Borg Category-Ratio 10 scale (Borg CR10), kinematics (center-of-gravity [CoG] height), kinetics (vertical ground-reaction force [Fz], normalized to body weight), and technology acceptance using an adapted Tele-healthcare Satisfaction Questionnaire-Wearable Technology (TSQ-WT). Participant-level data are the primary presentation. Condition effects were tested with exact nonparametric tests. RESULTS: Under linear assistance, 27 of 30 repetitions (90%) were successful (mean 4.50, SD 0.84; 4 of 6 participants at 5/5) and perceived exertion was the lowest of the 3 conditions (Borg CR10 mean 1.50, SD 1.38; lower than the rollator in 3 of 6 participants, unchanged in 2, higher in 1). Under S-shape assistance, 21 of 30 repetitions (70%) were successful (mean 3.50, SD 1.97; 3 of 6 at 5/5), with exertion comparable to the conventional rollator (mean 2.50, SD 2.43 vs mean 2.33, SD 1.63). All 6 completers achieved 5 of 5 repetitions with the conventional rollator, so robotic assistance did not increase the number of successful transfers in this cohort. Exact tests showed no significant condition effect on exertion (Friedman χ22=2.1; exact P=.40; Kendall W=0.18) or success (Friedman χ22=5.0, exact P=.11; Kendall W=0.42). Group CoG curves showed earlier, more monotonic elevation for linear, and per-participant Fz showed greater between-participant variability in load-transfer timing under S-shape. Technology acceptance was heterogeneous (TSQ-WT totals 22-77 of 80; 4 of 6 participants at 64 or higher). CONCLUSIONS: Powered STS assistance was feasible for most assisted transfers: 27 of 30 repetitions (90%) succeeded under the linear trajectory, which also produced the lowest mean perceived effort of the 3 conditions. The S-shape trajectory was more demanding, producing more partial completions and no effort reduction relative to the conventional rollator. In this first evaluation of SkyWalker with its intended users, the assistance profile, not powered assistance itself, is the variable to prioritize in further testing, and the results, which motivate trajectory personalization and brief familiarization, are informing the design of the next SkyWalker generation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Close-Proximity Vision-Guided Control and Performance Evaluation of a Mobile Robot for Sit-to-Stand Assistance.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2026
- Design and Evaluation of FALL-E: A Robotic Rollator for Studying Balance Response to Overground PerturbationACM Transactions on Human-Robot Interaction · 2026
- Sit-to-Stand Assistance for Patients with Parkinson's Disease Using a Lower-Limb Exoskeleton Robot.Bioengineering (Basel, Switzerland) · 2026
- DESIGN REFINEMENT AND TAKE-HOME TESTING OF A MOBILE MANUAL STANDING WHEELCHAIR.Proceedings of the ... Design of Medical Devices Conference. Design of Medical Devices Conference · 2026
- Understanding how demographic characteristics impact the level of physical activity children with neuromotor impairments experience while using a robot-assisted walkermedRxiv · 2026
- Upright Participation for Learners with Physical Disabilities: A Pilot Randomized Crossover Effectiveness-Implementation Trial of Robot-assisted Walking in SchoolsmedRxiv · 2026