Coexistence of AI Nurse and AI-Simulated Patient in Nursing Education Using a Bidirectional Fine-Tuning Pipeline: Development and Content Analysis Study.
Takeshi Koike, Yukie Majima
Faculty of Nursing, Seirei Christopher University, 3453 Mikatahara-cho, Chuo-ku, Hamamatsu, Japan, 81 053-439-1401. · Graduate School of Informatics, Osaka Metropolitan University, Osaka, Japan.
Key points
From the paper's conclusion- A 5-step bidirectional fine-tuning pipeline produced 2 specialized models whose joint deployment constitutes a design pattern for nursing education simulation. The preliminarily observed functional asymmetry between qualitative nurse-side variation and quantitative patient-side stabilization appears to underwrite the system's coherence, supporting 3 operating modes on consumer-grade hardware and deployable offline in disaster preparedness contexts. Third-party evaluation confirmed exploratory educational applicability, with all evaluators rating the system as usable, providing a foundation for future learner outcome studies.
Abstract
BACKGROUND: Simulated patient systems are essential in nursing education but face actor scarcity, instructor burden, cost, and disrupted continuity where in-person simulation cannot be sustained. Existing large language model (LLM)-based systems address these issues but treat the dialogic partner-the AI nurse-as a static prompt or unspecialized model, compromising data collection quality and pedagogical applicability. OBJECTIVE: We report (1) the construction of 2 specialized fine-tuned models, NURSE-ONE (AI nurse) and PATIENT-ONE (AI-simulated patient), via a 5-step bidirectional fine-tuning pipeline; (2) their evaluation using Berelson content analysis validated by independent human coders; (3) an exploratory third-party evaluation by nursing faculty; and (4) the design of a coexistence simulation ecosystem supporting 3 operating modes, including offline disaster preparedness applicability. METHODS: On a single consumer-grade graphics processing unit (NVIDIA RTX 4090; 24 GB video random access memory), the multimodal base model gemma4-E4B-it was fine-tuned via low-rank adaptation in five steps: (1) a 251-scenario base from 29 institutionally authored nursing care plans and 20 items from the 115th Japanese National Nursing Examination; (2) a provisional dialogue system (AutoGen v18, maxmsg=25) to collect training dialogues; (3) NURSE-ONE fine-tuning across 3 training volume conditions (245, 735, and 1225 cases); (4) 4-condition Berelson comparison; and (5) PATIENT-ONE fine-tuning on NURSE-ONE-generated dialogues with a 3-condition comparison. Interrater reliability was confirmed by 2 independent nursing experts (196 blinded utterances, κ=0.770) and corroborated by 2 LLM raters (κ=0.742). Ten nursing faculty evaluated 3 coexistence modes in a working web user interface (21-item rubric; item-level content validity index=1.00). RESULTS: Four-condition Berelson analysis (χ215=42.0, P<.001) identified the 735-case nurse-side condition (open question rate=21.5%) as NURSE-ONE; information collection rate reached 15.5% (~4× baseline) at 1225 cases. PATIENT-ONE A/B/C analysis (χ210=11.8, P=.30) showed no significant category shift but the lowest response length variability (SD 24.5) and highest information-providing rate (47.9%) at 735 cases, adopted as PATIENT-ONE. The 2 adapters appeared to operate on different axes-qualitative questioning style on the nurse side and quantitative response stability on the patient side-a preliminary observed pattern we term functional asymmetry, pending replication. Third-party evaluation rated the AI-simulated patient, AI nurse, and dyadic interaction at 90.3%, 69.0%, and 84.8%, respectively, with role maintenance at ceiling (mean 5, SD 0). All 3 modes met the prespecified 3-second latency threshold. CONCLUSIONS: A 5-step bidirectional fine-tuning pipeline produced 2 specialized models whose joint deployment constitutes a design pattern for nursing education simulation. The preliminarily observed functional asymmetry between qualitative nurse-side variation and quantitative patient-side stabilization appears to underwrite the system's coherence, supporting 3 operating modes on consumer-grade hardware and deployable offline in disaster preparedness contexts. Third-party evaluation confirmed exploratory educational applicability, with all evaluators rating the system as usable, providing a foundation for future learner outcome studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Large Language Model-Powered AI-Assisted Simulated Patient for Nursing Education: Quasi-Experimental Study.JMIR nursing · 2026
- Large Language Model-Based Virtual Patient Simulations in Medical and Nursing Education: A ReviewApplied Sciences · 2025
- Generative AI adaptive narratives to enhance nursing diagnostic reasoning: a classroom innovationBMC Nursing · 2026
- The Development and Evaluation of a Retrieval-Augmented Generation Large Language Model Virtual Assistant for Postoperative InstructionsBioengineering · 2025
- Virtual Reality-Enabled Physical AI Training for Supportive Nursing Robotics: Nurse-in-the-Loop, Site-Specific Conceptual Framework.JMIR nursing · 2026
- Experiences of Multiperspective Text-Based Debriefing Using Generative Artificial Intelligence for Nursing (GAIN) in Simulation.Computers, informatics, nursing : CIN · 2026