ReadCT: Parameter-Efficient 3D Chest CT Findings Generation Using Low- Rank Adaptation.

Maram Mahmoud A Monshi, Fahad Mahmoud Monshi

Department of Information Technology, College of Computers and Information Technology, Taif University, Taif, Saudi Arabia. · Department of Diagnostic Radiology, Al Hammadi Hospitals Al Suwaidi, Riyadh, Saudi Arabia.

Computational

Key points

From the paper's conclusion
  • ReadCT provides a research-stage demonstration of compact, parameter-efficient findings generation from 3D chest CT volumes. Prospective workflow evaluation, structured factual assessment, and sufficiently powered multi-reader studies are required before clinical use can be considered.

Abstract

INTRODUCTION/OBJECTIVE: Automatic report generation from Three-Dimensional (3D) chest Computed Tomography (CT) is computationally demanding. We evaluated whether a compact, parameter-efficient model could generate findings text directly from 3D non-contrast chest CT volumes within a tractable retrospective benchmark setting. METHODS: ReadCT encodes each standardized 3D volume using a lightweight 3D convolutional network, converts the global representation into compact visual-prefix tokens, refines the visual-text sequence with a single-layer Transformer encoder, and generates findings with a single-layer Long Short-Term Memory (LSTM) decoder. Low-Rank Adaptation (LoRA) was applied to selected projection layers while the embeddings and the decoder remained trainable. We trained and evaluated ReadCT on large-scale public chest CT resources, using CT-RATE (more than 25,000 scans with reports) as the primary benchmark. Performance was assessed using standard lexical and semantic report-generation metrics, and generalization was examined on an external dataset (BIMCV-R) without additional tuning. RESULTS: On the CT-RATE held-out test split, ReadCT achieved a Bilingual Evaluation Understudy (BLEU)-4 score of 29.17 and a BERTScore F1 of 89.51, with competitive performance relative to published CT report generation baselines evaluated on the same split. On BIMCV-R, lexical overlap decreased substantially, whereas BERTScore F1 was 81.26. DISCUSSION: This divergence indicates contextual embedding similarity despite substantial lexical and dataset shift; however, it does not establish factual, semantic, or clinical equivalence. The results demonstrate the retrospective computational feasibility of the proposed parameter-efficient design, while clinical accuracy and workflow utility were not prospectively evaluated. CONCLUSION: ReadCT provides a research-stage demonstration of compact, parameter-efficient findings generation from 3D chest CT volumes. Prospective workflow evaluation, structured factual assessment, and sufficiently powered multi-reader studies are required before clinical use can be considered.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

ReadCT: Parameter-Efficient 3D Chest CT Findings Generation Using Low- Rank Adaptation — Science Skim