Evaluating the Accuracy of Non-Invasive Pulsed-Wave Doppler Echocardiography in Measuring Fetal QT and PR Intervals: A Cross-sectional Study.
Feisal Rahimpour, Lida Jarahi, Hasan Birjandi, Mitra Ahmadian, Rasoul Raesi
Department of Pediatric Cardiologist, Interventional Electrophysiologist, Mashhad Cardiovascular Medical and Research Center, Mashhad University of Medical Sciences, Mashhad, Iran. · Department, Community Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
Key points
From the paper's conclusion- It is a practical, non-invasive, and easily accessible substitute for fMCG when it is not available for prenatal screening of cardiac repolarization and conduction abnormalities.
Abstract
INTRODUCTION: Congenital Long QT Syndrome (LQTS) is a common cause of potentially life-threatening ventricular arrhythmias and sudden cardiac death in infants and children. Fetal Magnetocardiography (fMCG) is available in only a few specialized centers worldwide and offers accurate measurements of the QT and PR intervals. The aim of this study was to assess the diagnostic accuracy of PW Doppler echocardiographic measurement of fetal QT and PR intervals compared with the available normative data for fMCG. METHODS: 576 pregnant women with singleton pregnancies (16-38 weeks' gestation) were studied in this cross-sectional study between 2022 and 2023 with detailed fetal echocardiograms. Standardized pulsed-wave Doppler techniques were used to measure the PR and QT intervals. Results were compared with published normative data for fMCG, adjusted for gestational age, and were also compared with contemporaneous fMCG in a subset of 42 fetuses. RESULTS: Mean QT interval (echo) was 270.0 ± 38.8 and mean PR interval was 119.3 ± 16.2. In the paired subset (n = 42), strong agreement was observed (PR ICC = 0.89 [95% CI: 0.81-0.94]; QT ICC = 0.82 [95% CI: 0.72-0.89]), with mean biases of +2.1 ms and +6.8 ms on Bland-Altman analysis, respectively. Sensitivity and specificity for the full cohort for prolonged intervals (> 95th percentile of GA-adjusted fMCG norms) were 85% and 78% (PPV 68%, NPV 90%). There were no clinically significant differences for PR interval or fetal heart rate, and there was no significant correlation between measured intervals and gestational age (p > 0.05). DISCUSSION: Pulsed-wave Doppler echocardiography is a reliable method for measuring fetal QT and PR intervals and is in good agreement with fMCG. CONCLUSION: It is a practical, non-invasive, and easily accessible substitute for fMCG when it is not available for prenatal screening of cardiac repolarization and conduction abnormalities.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optically Pumped Magnetometers for Fetal Arrhythmia Evaluation: Clinical Evidence and Implications for Health Technology Assessment.Medical sciences (Basel, Switzerland) · 2026
- Agreement between cardiac cycle time intervals and myocardial velocities measured by automated analysis of color tissue Doppler cine loops and by manual tracing of spectral pulsed-wave tissue Doppler waveforms of sheep fetal heart under normal and pathological conditions: An experimental study.Acta obstetricia et gynecologica Scandinavica · 2026
- Fetal Magnetocardiography Using Optically Pumped Magnetometers: A Literature Review.Biosensors · 2026
- pedQTNet: A Deep Learning Approach to Estimate Corrected QT Intervals from Multi-Lead Conventional ECG Waveforms in Pediatric PatientsJournal of Medical Systems · 2026
- Prediction of fetal lung maturity using the fetal pulmonary artery doppler wave parametersThe Egyptian Journal of Radiology and Nuclear Medicine · 2026
- A Case of Fetal Bradycardia, or Not? Pulseless Ventricular Tachycardia in a Fetus with Congenital Long QT Syndrome.Pediatric cardiology · 2026