A Simplified Modification of the Transseptal Puncture Technique to Optimize Percutaneous Mitral Balloon Commissurotomy in Addis Ababa, Ethiopia.
Mohammed Bedru Sebah, Jemal Haidar Ali
Internist, Consultant Interventional Cardiologist, Cardiac Center Ethiopia, Addis Ababa, Ethiopia. · Department of Public Health Nutrition, School of Public Health, Addis Ababa University, Addis Ababa, Ethiopia.
Key points
From the paper's conclusion- The innovative modified transseptal puncture approach demonstrated a safe and effective technique, with a high success rate for mitral valve balloon commissurotomy.
Abstract
INTRODUCTION: Transseptal catheterization is a critical step in percutaneous mitral balloon commissurotomy (PMBC), yet conventional techniques can be technically challenging and sometimes lead to procedural risks. Our study aimed to use a simplified modification to improve anatomical guidance and reduce complications. METHODS: This prospective multicenter study was conducted over one-year and included 161 patients with severe mitral stenosis who underwent PMBC using a modified septal puncture technique in Addis Ababa, Ethiopia. Data were entered and analyzed using SPSS version 25. Descriptive statistics were used to summarize patient characteristics and procedural outcomes. Continuous variables were expressed as mean ± standard deviation (SD) or median with range, as appropriate. Paired t-tests were used to compare pre- and post-procedural parameters, with a pvalue < 0.05 considered statistically significant. RESULTS: Our findings showed that the technique used was successful in all patients, with optimal results achieved in 160 (99.4%). Nonetheless, four patients developed new-onset atrial fibrillation during catheterization that resolved before discharge. The increase in mean mitral valve area and the reduction in transmitral mean gradient were statistically significant. The mean safety distance from the puncture site to the left atrial border was 24.8 mm (range 13 to 48 mm), while the average vertebral body height (VBH) was 17.3 mm (range 12 to 23 mm). The ratio of safety distance to VBH was 1.4 (range 1.0 to 2.4; SD = 0.26). DISCUSSION: Our study introduces a novel modification of the atrial septal puncture technique, simplifying the conventional approaches described by Inoue and Hung. The left atrial shadow, carinal angle, and VBH were identified as important radiographic landmarks for atrial septal puncture. CONCLUSION: The innovative modified transseptal puncture approach demonstrated a safe and effective technique, with a high success rate for mitral valve balloon commissurotomy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Inoue Balloon Mitral Commissurotomy Using Percutaneous Transvenous Approach inBabylon, IraqMedical Forum Monthly · 2026
- Transseptal versus left atrial approach for mitral valve surgery: A systematic review and meta-analysis.Asian cardiovascular & thoracic annals · 2026
- Same-session percutaneous closure of iatrogenic sinus of Valsalva rupture during transseptal puncture for balloon mitral valvotomy: a case report.European heart journal. Case reports · 2026
- Rescue transseptal percutaneous mitral balloon valvuloplasty for early bioprosthetic mitral valve thrombosis during VA-ECMO support: a case report.European heart journal. Case reports · 2026
- Application of the combined technique of novel transseptal puncture guidewire and steerable sheath in left atrial appendage occlusion: a preliminary feasibility case series.Frontiers in cardiovascular medicine · 2026
- Modified Transseptal BATMAN for Anterior Leaflet Modification in High-Risk Transcatheter Mitral Valve-in-Valve Replacements: A Case Series.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026