A Simplified Modification of the Transseptal Puncture Technique to Optimize Percutaneous Mitral Balloon Commissurotomy in Addis Ababa, Ethiopia.

Mohammed Bedru Sebah, Jemal Haidar Ali

Internist, Consultant Interventional Cardiologist, Cardiac Center Ethiopia, Addis Ababa, Ethiopia. · Department of Public Health Nutrition, School of Public Health, Addis Ababa University, Addis Ababa, Ethiopia.

Observational · n=161

Key points

From the paper's conclusion
  • The innovative modified transseptal puncture approach demonstrated a safe and effective technique, with a high success rate for mitral valve balloon commissurotomy.

Abstract

INTRODUCTION: Transseptal catheterization is a critical step in percutaneous mitral balloon commissurotomy (PMBC), yet conventional techniques can be technically challenging and sometimes lead to procedural risks. Our study aimed to use a simplified modification to improve anatomical guidance and reduce complications. METHODS: This prospective multicenter study was conducted over one-year and included 161 patients with severe mitral stenosis who underwent PMBC using a modified septal puncture technique in Addis Ababa, Ethiopia. Data were entered and analyzed using SPSS version 25. Descriptive statistics were used to summarize patient characteristics and procedural outcomes. Continuous variables were expressed as mean ± standard deviation (SD) or median with range, as appropriate. Paired t-tests were used to compare pre- and post-procedural parameters, with a pvalue < 0.05 considered statistically significant. RESULTS: Our findings showed that the technique used was successful in all patients, with optimal results achieved in 160 (99.4%). Nonetheless, four patients developed new-onset atrial fibrillation during catheterization that resolved before discharge. The increase in mean mitral valve area and the reduction in transmitral mean gradient were statistically significant. The mean safety distance from the puncture site to the left atrial border was 24.8 mm (range 13 to 48 mm), while the average vertebral body height (VBH) was 17.3 mm (range 12 to 23 mm). The ratio of safety distance to VBH was 1.4 (range 1.0 to 2.4; SD = 0.26). DISCUSSION: Our study introduces a novel modification of the atrial septal puncture technique, simplifying the conventional approaches described by Inoue and Hung. The left atrial shadow, carinal angle, and VBH were identified as important radiographic landmarks for atrial septal puncture. CONCLUSION: The innovative modified transseptal puncture approach demonstrated a safe and effective technique, with a high success rate for mitral valve balloon commissurotomy.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers