Key points

From the paper's conclusion
  • A transparent AI-assisted workflow can document harmonization, execute authordefined rules, and prioritize a heterogeneous public microRNA evidence set. The resulting shortlist is hypothesis-generating and requires independent tissue- and cell-level validation, as well as prospective clinical validation.

Abstract

INTRODUCTION/BACKGROUND: Reproducibility of circulating microRNA biomarkers in Alzheimer's disease remains limited because public studies vary across platforms, biofluids, cohort structures, and analytical methods. Direct cross-platform pooling can create apparent agreement while obscuring biological and pre-analytical heterogeneity. To develop a transparent, conservative workflow for prioritizing circulating microRNA candidates for Alzheimer's disease across public datasets without raw cross-platform pooling. MATERIALS AND METHODS: AIM-AD used HMDD v4.0 as an Alzheimer's-focused candidate layer and evaluated retained candidates across two plasma AD-versus-control GEO datasets: GSE305625 (targeted qPCR; 71 AD, 74 controls) and GSE215789 (small RNA sequencing; 23 AD, 21 controls). GSE120584 serum AD-versus-control data (microarray; 1021 AD, 288 controls) were used only as contextual serum evidence. Direction, within-dataset support, serum status, and cautionary modifiers were integrated through documented rule-based prioritization. RESULTS: Of 50 harmonized plasma-overlap candidates, 34 (68.0%) had concordant plasma directions: 29 were lower in AD, and 5 were higher in AD; 16 were discordant. Rule-based prioritization retained 0 candidates in Priority 1, 18 in Priority 2, 1 in Watchlist, and 31 in Deprioritize. Fourteen candidates had q ≤ 0.10 in GSE305625; none reached raw p ≤ 0.10 or q ≤ 0.10 in GSE215789. The output is therefore a hypothesis-generating shortlist, not independent validation. DISCUSSION: The prioritization framework deliberately treats AIM-AD as a pre-validation shortlisting workflow rather than a diagnostic classifier, emphasizing cross-dataset plasma-direction concordance, source-aware interpretation, and conservative handling of biofluid and platform heterogeneity. CONCLUSION: A transparent AI-assisted workflow can document harmonization, execute authordefined rules, and prioritize a heterogeneous public microRNA evidence set. The resulting shortlist is hypothesis-generating and requires independent tissue- and cell-level validation, as well as prospective clinical validation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers