Real-Time Digital Quantification of Air-Leak Flow to Guide Endobronchial Watanabe Spigot Placement for Persistent Air Leak: A 12-Year Single-Center Experience.
Yoshio Nakano, Gen Masuda, Norio Okamoto, Iwao Gohma
Department of Respiratory Medicine, Sakai City Medical Center, Japan.
Key points
From the paper's conclusion- Objective To describe the real-time digital quantification of the air-leak flow during endobronchial Watanabe spigot (EWS) placement for persistent air leak and to relate the quantified flow to the clinical outcomes.Methods The primary outcome was the immediate change in the air-leak flow before and after EWS placement in the digital group.
Abstract
Objective To describe the real-time digital quantification of the air-leak flow during endobronchial Watanabe spigot (EWS) placement for persistent air leak and to relate the quantified flow to the clinical outcomes.Methods The primary outcome was the immediate change in the air-leak flow before and after EWS placement in the digital group. The secondary outcomes were leak-site identification, single-session cure, final cessation without surgery, chest tube duration, and safety. We also related the post-placement flow and the interval between the fulfilment of the removal criterion and actual removal to the drainage course. The between-group comparison was exploratory.Patients Twenty-seven consecutive patients with pneumothorax or empyema with bronchopleural fistula undergoing EWS placement between March 2014 and January 2026; 18 were managed with digital drainage (Thopaz/Thopaz+) and 9 with conventional suction, at the physician's discretion.Results The air-leak flow decreased immediately after EWS placement [median 525 (interquartile range 200-1,000) to 5 (0-138) mL/min]. The immediate flow did not predict whether the tube was removed (76.9% at 100 mL/min or less vs. 80.0% above), but did predict how quickly: median 9, 12.5, and 16.5 days for flows of 0, 100 mL/min or less, and higher. The removal criterion (20 mL/min or less) was met a median of 0 days after placement, yet the tube stayed for 6.5 days longer. The responsible bronchus was identified in 66.7% of patients, and final cessation without surgery was achieved in 77.8% of patients.Conclusion Real-time digital quantification confirmed bronchial occlusion and predicted drainage duration but not eventual clinical success. The interval between the fulfilment of the removal criterion and actual removal warrants a prospective study.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Persistent air leak: from evaluation to management.Current opinion in pulmonary medicine · 2026
- Valve Expectoration After Endobronchial Valve Placement: Potential Utility of Computed Tomography-Based Airway Sizing-A Case Report.Respirology case reports · 2026
- Endoluminal approaches to postoperative air leaks.Journal of thoracic disease · 2026
- Endobronchial valves placement for persistent air leaks in critically ill patients: chest tube removal and competing risk of death.Frontiers in medicine · 2026
- Endobronchial valves for management of persistent air leak in advanced cystic fibrosis: A case report and review of literature.Respiratory medicine case reports · 2026
- Effect of Ultrasound-Guided versus Conventional Lung Recruitment on End-of-Surgery Atelectasis in Adults Aged 45-74 Years Undergoing Prone-Position Spinal Surgery: A Randomized Controlled Trial.Therapeutics and clinical risk management · 2026