Association Between Endothelial Activation and Stress Index and Microalbuminuria.
Wenhui Huang, Fang Liu, Yangfan Hu, Guoyan Xu, Liangdi Xie, Tingjun Wang
Department of General Practice, the First Affiliated Hospital, Fujian Medical University, Fuzhou, Fujian, People's Republic of China.
Key points
From the paper's conclusion- This study provides evidence that EASIX, a composite marker derived from routine blood tests, is independently associated with microalbuminuria. A threshold of 0.625 for the EASIX may warrant further investigation in longitudinal studies.
Abstract
BACKGROUND: The aim of this study was to investigate the association between endothelial activation and stress index (EASIX), a composite marker of endothelial dysfunction, and microalbuminuria. METHODS: This cross-sectional study included adult patients from Departments of General Practice and Geriatrics at the First Affiliated Hospital of Fujian Medical University between January 2017 and December 2023. Microalbuminuria was defined as a urinary albumin-to-creatinine ratio (UACR) of 30-300 mg/g. EASIX was calculated as lactate dehydrogenase (U/L) × serum creatinine (mg/dL) / platelet count (109/L). The association of EASIX with microalbuminuria was evaluated using logistic regression models, restricted cubic splines (RCS), and subgroup analyses. RESULTS: Among 3,126 patients, 403 (12.9%) had microalbuminuria and exhibited significantly higher EASIX levels compared with those with normal UACR [median (P25~P75): 0.63 (0.47-0.90) vs 0.62 (0.48-0.82) mg/g, P = 0.019]. Multivariate linear regression identified EASIX as an independent factor for lnUACR (β = 0.100, 95% CI: 0.115~0.233, P<0.001). Logistic regression further showed that EASIX was independently associated with microalbuminuria (OR = 1.420, 95% CI:1.167~1.728, P < 0.001). In the fully adjusted model, EASIX quartiles remained independently associated with microalbuminuria (OR = 1.395, 95% CI: 1.147~1.698, P < 0.001). RCS analysis revealed a U-shaped non-linear association (P for non-linear = 0.007), with an inflection point at EASIX = 0.625, above which the risk of microalbuminuria increased significantly. This association remained consistent across subgroups stratified by age, sex, body mass index (BMI), and hypertension or diabetes status in patients with EASIX > 0.625, with no significant interactions. CONCLUSION: This study provides evidence that EASIX, a composite marker derived from routine blood tests, is independently associated with microalbuminuria. A threshold of 0.625 for the EASIX may warrant further investigation in longitudinal studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Association between Endothelial Activation and Stress Index (EASIX) and uric acid levels: A cross-sectional analysis based on the NHANES.Medicine · 2026
- Prognostic Role of the Endothelial Activation and Stress Index (EASIX) in Functional Outcomes and Mortality After Acute Ischemic Stroke: A Retrospective Pilot Cohort StudyJournal of Cardiovascular Development and Disease · 2026
- The relationship between endothelial activation and stress index (EASIX) and the incidence of major adverse cardiovascular events in acute myocardial infarction patients admitted in emergency department.BMC emergency medicine · 2026
- Prognostic Value of the Endothelial Activation and Stress Index (EASIX) in Critically Ill Patients With Ischemic Stroke: A MIMIC-IV Database Analysis.Brain and behavior · 2026
- Endothelial Activation and Stress Index is Associated with a Non-Dipping Blood Pressure Pattern in Type 2 Diabetic Patients and Newly Diagnosed Hypertension: A Retrospective Study.Journal of inflammation research · 2026
- The role of the EASIX score in patients with hypertension: a cross-sectional studyThe Egyptian Heart Journal · 2025