Research and reports in urology

Diagnostic Evaluation of Automated Urine Particle Digital Imaging Device for Urinary Tract Infection Stewardship: A Cross-Sectional Laboratory-Based Study in Single Indonesian Tertiary Hospital.

Adhi Kristianto Sugianli, Fellani Fellani, Tiene Rostini

Department of Clinical Pathology, Faculty of Medicine Universitas Padjadjaran, Bandung, 40161, Indonesia.

Observational

Key points

From the paper's conclusion
  • Digital imaging of urine particles is a valuable tool for preliminary bacteriuria information in diagnostic stewardship. Incorporating this approach into a concept of UTIs diagnostic stewardship workflow-by offering an initial bacterial morphological classification-helps improve patient diagnosis and guide the use of empirical antibiotic based on local antibiogram guidance or clinical consensus within the healthcare setting.

Abstract

PURPOSE: Urinary tract infections (UTIs) remain a significant global challenge where gold-standard cultures impose critical diagnostic delays. Rapid screening of UTIs is essential for antimicrobial stewardship programs to prevent empirical antibiotic overuse. This study evaluates the diagnostic accuracy of the UD-10 digital imaging system for bacteriuria detection compared to traditional culture. PATIENTS AND METHODS: A prospective cross-sectional study at an Indonesian tertiary hospital (May-July 2024) analyzed 186 urine culture specimens, with screening threshold of >150 bacteria/µL as determined by UF-4000. The UD-10 utilized a charge-coupled device camera with objective lens to capture digital images of unstained, uncentrifuged urine. Performance was assessed via sensitivity (Sn), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), accuracy (ACC), and Cohen's kappa (k). These parameters provided the framework for evaluating the clinical utility of automated digital imaging. RESULTS: Culture positivity was 65.1%, with Gram-negative bacteria representing 89.8% of isolates, primarily Escherichia coli. The UD-10 demonstrated Sn of 80.9%, PPV of 83.1%, NPV of 66.2%, and ACC of 76.9% in predicting growth. Bacteriuria agreement was moderate with culture (k = 0.497) and these findings demonstrate the potential for enhanced diagnostic stewardship through rapid clinical intervention. CONCLUSION: Digital imaging of urine particles is a valuable tool for preliminary bacteriuria information in diagnostic stewardship. Incorporating this approach into a concept of UTIs diagnostic stewardship workflow-by offering an initial bacterial morphological classification-helps improve patient diagnosis and guide the use of empirical antibiotic based on local antibiogram guidance or clinical consensus within the healthcare setting.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers