Patient preference and adherence

Measurement Properties of Spanish Versions of Two Exercise Self-Efficacy Scales in People with Multiple Sclerosis.

Carme Santoyo-Medina, Montserrat Janer, Cristina Lidón-Moyano, Edwin Roger Meza-Murillo, Ingrid Galán, Xavier Montalban, Caritat Bagur-Calafat, Jaume Sastre-Garriga,

Neurology-Neuroimmunology Department & Neurorehabilitation Unit, Multiple Sclerosis Centre of Catalonia, Vall D'Hebron University Hospital, Barcelona, Spain. · Department of Physiotherapy, Faculty of Medicine and Health Sciences, Universitat Internacional De Catalunya, Sant Cugat del Vallès, Spain.

Key points

From the paper's conclusion
  • The EXSE-Sp and ESE-Sp demonstrate good measurement properties and are suitable for assessing exercise self-efficacy in Spanish PwMS. These patient-reported measures may support clinical assessment, patient-centred rehabilitation planning, and evaluation of interventions targeting long-term PA participation.

Abstract

BACKGROUND: Regular physical activity (PA) is recommended for people with multiple sclerosis (PwMS), yet long-term exercise adherence remains suboptimal. Exercise self-efficacy is a key patient-reported determinant of exercise initiation and maintenance, making its assessment relevant for both clinical practice and research. Although the Exercise Self-Efficacy Scale (EXSE; McAuley et al 1993) and the Exercise Self-Efficacy (ESE; Neupert et al 2009) have been previously used, validated Spanish versions are not available. This study aimed to translate, culturally adapt, and evaluate the measurement properties of the Spanish versions of the EXSE-McAuley (EXSE-Sp) and ESE-Neupert (ESE-Sp) in Spanish PwMS. METHODS: The EXSE-McAuley and ESE-Neupert were translated and cross-culturally adapted into Spanish according to Beaton's guidelines. Ninety-three Spanish PwMS completed both questionnaires twice, with a 7-10-day interval between assessments at the end of their rehabilitation program. Structural validity, internal consistency, test-retest reliability, measurement error, and construct validity were evaluated following the COSMIN framework. RESULTS: Both instruments demonstrated a unidimensional structure with adequate structural validity. Internal consistency was excellent for the EXSE-Sp (Cronbach's α = 0.977) and good for the ESE-Sp (α = 0.896). Test-retest reliability was excellent (ICC = 0.992 and 0.969, respectively), with low measurement error (SEM = 2.83 and 1.20 points; Smallest Detectable Change [SDC] = 7.86 and 3.33 points, respectively). Construct validity was supported by the expected moderate positive correlation between the two scales (r = 0.56, p < 0.001), indicating that they assess related yet complementary aspects of exercise self-efficacy. CONCLUSION: The EXSE-Sp and ESE-Sp demonstrate good measurement properties and are suitable for assessing exercise self-efficacy in Spanish PwMS. These patient-reported measures may support clinical assessment, patient-centred rehabilitation planning, and evaluation of interventions targeting long-term PA participation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers