Evaluation of Intraocular Lens (IOL) Formulae Utilizing Posterior Corneal Power in Post-Laser Vision Correction (LVC) Eyes.
Hasan Alsetri, Mitchell P Weikert, Nicole Fram, Jared Pagal, Karolinne Maia Rocha, Marcela Feltrin De Barros, Daniel H Chang, Brandon D Ayres,
Advanced Vision Care, Los Angeles, CA, USA. · Cullen Eye Institute, Baylor College of Medicine, Houston, TX, USA.
Key points
From the paper's conclusion- EVO 2.0-TK demonstrated the highest overall accuracy among the formulae evaluated in both post-myopic and post-hyperopic LVC eyes, while Barrett True K-TK also performed well, with both formulae achieving ≥75% of eyes within ±0.50 D in both LVC subgroups.
Abstract
PURPOSE: To evaluate the accuracy of intraocular lens (IOL) power calculation formulae incorporating posterior corneal power vs traditional keratometry in post-laser vision correction (LVC) eyes undergoing cataract surgery. PATIENTS AND METHODS: This multicenter study (7 sites) combined retrospective chart review and prospective enrollment of adult cataract surgery patients with prior myopic or hyperopic LVC (one study eye per patient). Preoperative biometry was obtained by swept-source optical coherence tomography, and refractive prediction accuracy was compared across six IOL formulae (Barrett True K-AK, Barrett True K-TK, EVO 2.0-AK, EVO 2.0-TK, Haigis-TK, and Shammas-Cooke) in terms of trueness (mean refractive prediction error [RPE]), precision (RPE dispersion), and accuracy (absolute error metrics and proportion of eyes within ±0.5 D and ±1.0 D). RESULTS: A total of 154 eyes were included. The proportion of eyes within ±0.5 D of predicted refraction was highest with EVO 2.0-TK in both post-myopic (77%) and post-hyperopic (88%) LVC eyes, with Barrett True K-TK next highest (75% and 78%, respectively); in post-myopic eyes, EVO 2.0-TK was also the only formula whose mean RPE did not differ significantly from zero. CONCLUSIONS: EVO 2.0-TK demonstrated the highest overall accuracy among the formulae evaluated in both post-myopic and post-hyperopic LVC eyes, while Barrett True K-TK also performed well, with both formulae achieving ≥75% of eyes within ±0.50 D in both LVC subgroups.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biometry-Guided IOL Formula Selection in Post-Laser Vision Correction Eyes.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- No-History IOL Power Calculation After Myopic Laser Vision Correction: A Multicenter Retrospective Database Study of 14 Formulas With and Without Posterior Corneal Curvature.American journal of ophthalmology · 2026
- Accuracy of Intraocular Lens Power Calculation Formulas Using Total Keratometry in Eyes With Previous Radial KeratotomyJournal of Refractive Surgery · 2026
- Comparative accuracy of Barrett true-K and Haigis-L formulas for intraocular lens power calculation in post-laser-assisted in situ keratomileusis cataract surgeryGlobal Journal of Cataract Surgery and Research in Ophthalmology · 2026
- Enhanced keratometry for IOL power calculation after myopic LASIK: a multi-device comparison.Eye (London, England) · 2026
- Hydrophobic Acrylic Trifocal IOL in Post-Laser Refractive Surgery Eyes: Visual Performance, Predictability, and Patient-Reported Outcomes.Journal of ophthalmology · 2026