Medical devices (Auckland, N.Z.)

Adverse Events Reported with Vivistim Paired Vagus Nerve Stimulation: A Postmarketing Database Analysis.

Divya Ganisetti, Sai Tharun Reddy Gopannagari, Lakshmi Sai Deepak Reddy Velugoti

Department of Internal Medicine, Atal Bihari Vajpayee Institute of Medical Sciences & Dr Ram Manohar Lohia Hospital, New Delhi, India. · Department of Internal Medicine, Garden City Hospital, Michigan State University, Garden City, MI, USA.

Key points

From the paper's conclusion
  • The reviewers classified most Vivistim reports as implant-related. Persistent symptoms and additional procedures described in these reports may help clinicians counsel patients about possible postoperative problems. Incomplete follow-up limited assessment of recovery. Underreporting and the lack of data on the number of patients treated limit interpretation; complication rates and causal relationships cannot be established from these reports.

Abstract

BACKGROUND: Vivistim pairs vagus nerve stimulation with rehabilitation to improve arm function after chronic ischemic stroke. Reports from routine clinical use may describe complications and treatment needs not fully captured in clinical trials. AIM: To characterize reported adverse events involving Vivistim and their documented management and clinical outcomes. MATERIAL AND METHODS: We searched the United States Food and Drug Administration's Manufacturer and User Facility Device Experience database on October 4, 2026, for reports received from August 27, 2021, the date of device approval, through October 4, 2026. Two reviewers independently examined 59 unique reports. Each report was assigned to one primary category and subcategory. Management and outcomes were recorded when available, and findings were summarized as counts and percentages. RESULTS: The reviewers classified 36 reports (61.0%) as implant-related problems, 10 (16.9%) as device and connection problems, and 11 (18.6%) as other clinical events. Two reports (3.4%) contained insufficient information. Infection and wound problems were the largest subcategory, with 12 reports (20.3%), followed by voice and swallowing problems in 10 (16.9%). Management included antibiotics, voice-directed treatment, implant repositioning, component replacement, and device removal. Normal impedance was documented after the lead connection was secured in both low-impedance reports. Clinical outcomes were documented in 14 reports (23.7%), including five with improvement without documented resolution and three with persistent symptoms without clear improvement. Outcomes were unavailable or unclear in 45 reports (76.3%). CONCLUSION: The reviewers classified most Vivistim reports as implant-related. Persistent symptoms and additional procedures described in these reports may help clinicians counsel patients about possible postoperative problems. Incomplete follow-up limited assessment of recovery. Underreporting and the lack of data on the number of patients treated limit interpretation; complication rates and causal relationships cannot be established from these reports.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers