A Clinical Connectivity Dependency Profile for Connected Medical Devices to Guide Care During Network and Service Disruptions.
Osman Diriye Hussein, Mohamed Mustaf Ahmed
Faculty of Engineering & Built Environment, SIMAD University, Mogadishu, Somalia. · Faculty of Medicine and Health Sciences, SIMAD University, Mogadishu, Somalia.
Key points
From the paper's conclusion- Its terminology, implementation burden, and usefulness require empirical evaluation across device classes and care settings, including whether it improves the recognition of clinically important dependency failures and the selection of appropriate fallback actions.
Abstract
Connected medical devices increasingly depend on networks, gateways, cloud services, and external software for clinically relevant monitoring, therapy, alarms, documentation, analytics, and decision-making support. Although existing regulatory and cybersecurity guidance addresses communication disruption, resilience, interoperability, and continuity of clinical operations, clinicians may still lack a concise device-specific account of what changes when a connectivity dependency becomes unavailable. This commentary proposes a clinical connectivity dependency profile that translates technical dependency information into guidance that clinicians can act on during disruption and recovery. The proposed profile comprises six domains, covering which clinical functions are retained, degraded, or unavailable, together with data and alarm continuity, degraded-state communication, fallback arrangements, recovery and data reconciliation, and external dependencies and lifecycle changes. Manufacturers would describe product-level behavior and relevant dependency changes, whereas healthcare organizations would define local staffing, escalation, fallback, and reconciliation arrangements. The profile can support procurement, local risk assessment, downtime planning, incident response, recovery verification, and multidisciplinary communication without replacing existing cybersecurity disclosures, labeling, or institutional downtime plans. Its terminology, implementation burden, and usefulness require empirical evaluation across device classes and care settings, including whether it improves the recognition of clinically important dependency failures and the selection of appropriate fallback actions. This paper aims to define the proposed profile, clarify responsibilities for its maintenance and use, and identify priorities for evaluation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical-Protocol-Aware Cyber Resilience for Connected Clinical Technologies Under AI-Enabled Adversarial ConditionsarXiv · 2026
- Medical device availability under system degradation: a dependency-based framework for adaptive responses and risk-informed decision-making.GMS hygiene and infection control · 2026
- User Perceptions of Security and Privacy in Connected Home IoMT: Implications for Interoperability and GovernanceFuture Internet · 2026
- Medical Cyber-Physical SystemsACM Transactions on Cyber-Physical Systems · 2026
- From Connected Devices to Intelligent Care: Integrating Medical Devices, Digital Health, Functional Precision Oncology, and Global Healthcare DeliveryJournal of Bioscience & Biomedical Engineering · 2026
- Artificial Intelligence-Enabled Medical Diagnosis in the Internet of Medical Things: An End-to-End Survey of Connected Sensing, Distributed Intelligence, Clinical Applications, and Validation.Diagnostics (Basel, Switzerland) · 2026