Medical devices (Auckland, N.Z.)

Comparison of Two Sutures for Closing the Gastroenterostomy in Laparoscopic One-Anastomosis Gastric Bypass (OAGB) Surgery: A Randomized Study with Monocryl Spiral Knotless Tissue Control Device (Stratafix Spiral 2-0, Ethicon Inc.) versus Traditional Polyglactin Multifilament Suture (Vicryl Plus 2-0, Ethicon Inc.).

Lisa Pelzer, Sara Schramm, Karl Peter Rheinwalt, Andreas Plamper

Department of Bariatric, Metabolic and Plastic Surgery, St. Franziskus Hospital, Cologne, North Rhine-Westphalia, Germany. · Department of Physician Assistance, Fliedner University of Applied Science, Düsseldorf, North Rhine-Westphalia, Germany.

Randomised · n=100

Key points

From the paper's conclusion
  • The used barbed suture enables time savings in laparoscopic OAGB surgery without negatively affecting patient safety.

Abstract

INTRODUCTION: Efficiency and patient safety are central to bariatric surgery. The study aims to determine differences in suture time, total operation time, and postoperative complications using barbed (StratafixTM Spiral Monocryl 2-0, Ethicon Inc.) compared to braided suture material (VicrylTM Plus 2-0, Ethicon Inc.) for closing the gastroenterostomy in laparoscopic one-anastomosis gastric bypass (OAGB) surgery. METHODS: A prospective, randomized, controlled, monocentric study was conducted. N=100 patients requiring laparoscopic OAGB surgery were assigned in a 1:1 ratio to the groups with barbed or braided suture material. The recruitment phase lasted 36 months and began in November 2020. Follow-up was six months. Clinical data on admission and follow-up, suture time, total operation time, and intra- and postoperative complications were determined. Descriptive statistics were performed. The association between the suture material and the suture and total operation time was determined using linear regression to estimate beta-coefficients and 95%-confidence intervals (95% CI). RESULTS: Suture and total operation time were measured in 50 patients with barbed and 44 patients with braided suture material. N=71 (75.5%) patients were female, the mean±SD age was 39.8±12.0 years, the preoperative Body Mass Index 52.2±4.4 kg/m2. The median (Q1; Q3) suture and total operation time was 13.72 (11.47; 15.51) min and 75.00 (64.75; 85.00) min in the group with the braided and 8.97 (7.78; 10.48) min and 65.50 (60.00; 75.25) min in the group with the barbed suture material. The mean suture time was 4.75 (95% CI: 3.48; 6.02) min and the mean total operation time 8.04 (95% CI: 2.47; 13.61) min shorter in the barbed group compared to the braided suture group. The six-month follow-up was completed in 49 patients with barbed and 41 patients with braided suture material. No complications related to the anastomosis occurred. CONCLUSION: The used barbed suture enables time savings in laparoscopic OAGB surgery without negatively affecting patient safety.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Comparison of Two Sutures for Closing the Gastroenterostomy in Laparoscopic One-Anastomosis Gastric Bypass (OAGB) Surgery: A Randomized Study with Monocryl Spiral Knotless Tissue Control Device (Stratafix Spiral 2-0, Ethicon Inc.) versus Traditional Polyglactin Multifilament Suture (Vicryl Plus 2-0, Ethicon Inc.) — Science Skim