Clinical Outcomes of Contemporary Frozen Elephant Trunk Prostheses and the Ascyrus Medical Dissection Stent in Aortic Arch Surgery: A Systematic Review and Proportional Meta-Analysis.

Matti Jubouri, Abdelaziz O Surkhi, Rohan Chikhal, Rami S N Alaraj, Aya Hammad, Yousif F Jubouri, Marco David Bokobza De la Rosa, Noor Halaseh,

Queen Elizabeth Hospital, University Hospitals Birmingham, Birmingham, UK. · Faculty of Medicine, Al-Quds University, Jerusalem, Palestine.

Meta-analysis

Key points

From the paper's conclusion
  • Contemporary FET prostheses and the AMDS were associated with broadly acceptable reported outcomes within their respective clinical settings. However, the predominantly observational evidence, heterogeneous case mix and differing device indications preclude definitive conclusions regarding comparative superiority. The pooled values should be used as descriptive benchmarks. Device selection should therefore be individualised according to aortic pathology, anatomy, operative urgency and institutional expertise. Prospective comparative studies using standardised outcome definitions and appropriate risk adjustment are required.

Abstract

INTRODUCTION: The frozen elephant trunk (FET) technique is an established strategy for complex aortic arch and descending thoracic aortic pathology. Several covered FET prostheses are available, while the Ascyrus Medical Dissection Stent (AMDS) represents a distinct uncovered hybrid arch adjunct used principally during open repair of acute type A dissection. This systematic review evaluated the reported clinical and aortic outcomes of contemporary FET prostheses and the AMDS. METHODS: MEDLINE, Embase, Scopus and Web of Science were searched from inception to January 2025 in accordance with PRISMA 2020 and the Cochrane Handbook. Random-effects proportional meta-analysis and exploratory study-level meta-regression were undertaken for Thoraflex, E-vita, Frozenix and Cronus, with the AMDS retained as a separate device stratum. Results were reported with 95% confidence intervals (CIs). RESULTS: A total of 114 studies encompassing 13,051 patients were included. Pooled all-cause mortality over the reported follow-up was 13.2% (95% CI 11.2-15.7%), while combined 30-day/in-hospital mortality was 8.4% (95% CI 7.4-9.5%), ranging from 5.1% to 14.5% across device strata. Five-year survival was 80.0% (95% CI 75.6-83.8%). Permanent neurological deficit ranged from 4.0% to 8.8%, and spinal cord ischaemia or paraplegia ranged from 0% to 7.0%. The pooled reintervention rate was 12.7% (95% CI 10.6-15.2%). Distal stent-induced new entry ranged from 0% to 8.9%, and endoleak ranged from 3.2% to 7.5%. Both clinical and statistical heterogeneity was substantial for several outcomes, and the device strata differed materially in pathology, urgency, age, operative strategy, and follow-up. CONCLUSION: Contemporary FET prostheses and the AMDS were associated with broadly acceptable reported outcomes within their respective clinical settings. However, the predominantly observational evidence, heterogeneous case mix and differing device indications preclude definitive conclusions regarding comparative superiority. The pooled values should be used as descriptive benchmarks. Device selection should therefore be individualised according to aortic pathology, anatomy, operative urgency and institutional expertise. Prospective comparative studies using standardised outcome definitions and appropriate risk adjustment are required.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Clinical Outcomes of Contemporary Frozen Elephant Trunk Prostheses and the Ascyrus Medical Dissection Stent in Aortic Arch Surgery: A Systematic Review and Proportional Meta-Analysis — Science Skim