Journal of multidisciplinary healthcare

A Transformer-Based Risk Prediction Model for Contrast Media Extravasation During High-Pressure Injection: A Dual-Center Study with External Validation.

Xi Zhu, Zhuqing Bao, Zhen Hu, Zengpeng Zhao, Chao Wang, Jinzhao Zou, Li Liu, Wennuo Huang,

School of Biological Sciences and Medical Engineering, Southeast University, Nanjing, Jiangsu, People's Republic of China. · Department of Emergency, Northern Jiangsu People's Hospital, Yangzhou, Jiangsu, People's Republic of China.

Observational · n=35,537

Key points

From the paper's conclusion
  • The model showed acceptable discriminative ability and generalizability across two centers, but remains a retrospective research prototype: because a rare-event model with high specificity still generates many false-positive alerts, its outputs require local recalibration and the alert threshold has not been clinically optimized. Prospective multicenter validation is therefore needed before clinical deployment.

Abstract

PURPOSE: To assess whether a Transformer-based deep learning model can predict contrast media extravasation (CME) risk before high-pressure intravenous iodinated contrast injection, and to provide an automated screening tool for high-risk patients before contrast-enhanced CT. PATIENTS AND METHODS: We retrospectively analysed 35,537 patients who underwent contrast-enhanced CT between November 2023 and June 2025 at Northern Jiangsu People's Hospital (internal cohort, n = 26,126; 0.88% CME-positive) and its South Branch (external validation, n = 9,411; 0.99% CME-positive), an overall CME-positive rate of 0.91%. Sixteen demographic, clinical, injection and nursing variables were used. A Transformer encoder model (three stacked encoder blocks) was trained with a batch-adaptive hard negative sample-corrected Focal Loss for extreme class imbalance, with class weights recalculated per mini-batch and an extra penalty on hard negative samples; perturbation-based feature attribution was also performed. Internal five-fold cross-validation was followed by independent external validation. Metrics included accuracy, recall, specificity, positive and negative predictive value, F1-score, Cohen's Kappa, Matthews correlation coefficient (MCC) and area under the ROC curve (AUC). RESULTS: Internal five-fold cross-validation gave an accuracy of 93.07% ± 0.76%, recall of 66.80% ± 2.16%, specificity of 93.31% ± 0.79% and AUC 0.907; external validation gave 92.71%, 63.44%, 93.00% and 0.862. Cohen's Kappa was 0.12-0.15 (internal mean 0.13) and MCC 0.21-0.23 (internal mean 0.22). Puncture site, contrast agent viscosity, total injection volume and venous thrombosis were high-contribution features (>10%); injection rate, diabetes, sex, age, BMI, VIA scale, malignant tumor history and patient source contributed 1-10%. CONCLUSION: The model showed acceptable discriminative ability and generalizability across two centers, but remains a retrospective research prototype: because a rare-event model with high specificity still generates many false-positive alerts, its outputs require local recalibration and the alert threshold has not been clinically optimized. Prospective multicenter validation is therefore needed before clinical deployment.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers