Delayed Recognition of a Cuff-Level Tracheal Rupture After Double-Lumen Endotracheal Tube Intubation for Thoracic Surgery: A Case Report.
JongHyun Baek, Min Gang Kwon, Eun Kyung Choi
Department of Thoracic and Cardiovascular Surgery, Yeungnam University College of Medicine, Daegu, Republic of Korea. · Department of Anesthesiology and Pain Medicine, Yeungnam University College of Medicine, Daegu, Republic of Korea.
Key points
From the paper's conclusion- Tracheal cuff injuries after DLT intubation may initially remain undetected. Persistent postoperative air leakage, subcutaneous emphysema, or failure of lung re-expansion should prompt early bronchoscopic evaluation, with careful inspection of the tracheal cuff level.
Abstract
BACKGROUND: Double-lumen endotracheal tubes (DLTs) are widely used to facilitate one-lung ventilation during thoracic surgery and are generally considered safe. However, tracheobronchial rupture is a rare but potentially life-threatening complication. Injuries occurring at the tracheal cuff level may initially remain clinically occult because the inflated cuff can obscure the injured area during bronchoscopic examination. CASE PRESENTATION: An 81-year-old man underwent left upper lobectomy for lung adenocarcinoma using a left-sided DLT. The procedure was converted from VATS to an anterolateral mini-thoracotomy because of persistent diffuse oozing. Ten hours postoperatively, he required emergent reoperation for intrathoracic bleeding. Persistent air leakage, left lung atelectasis, and progressive subcutaneous emphysema subsequently developed. Bronchoscopy on postoperative day (POD) 6 demonstrated a posterolateral tracheal wall defect at the membranous-cartilaginous junction, estimated to measure at least 1-1.5 cm. Exact measurement was limited by oxygen desaturation. Initial conservative management was undertaken; however, the air leak and failure of lung re-expansion persisted. Repeat bronchoscopy on POD12 showed no appreciable improvement in the defect and confirmed that the defect was located approximately 5 cm above the carina. Definitive surgical repair was performed through a left thoracotomy on POD13. The defect was primarily closed using 4-0 Prolene sutures, and intraoperative bronchoscopy and air-leak testing confirmed closure. CONCLUSION: Tracheal cuff injuries after DLT intubation may initially remain undetected. Persistent postoperative air leakage, subcutaneous emphysema, or failure of lung re-expansion should prompt early bronchoscopic evaluation, with careful inspection of the tracheal cuff level.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Hidden Airway Injury: Delayed Diagnosis of Tracheal Disruption After Penetrating Neck Trauma.Cureus · 2026
- Left main bronchus injury incurred during video double-lumen endobronchial tube intubation: A case report.Respiratory medicine case reports · 2026
- Tracheal Laceration and Endotracheal Tube Cuff Rupture During Thyroidectomy: A Case Report and Literature Review.Cureus · 2026
- Stepwise versus one-step intubation strategy for tracheal injury in thoracic surgery: a multicenter randomized controlled trial protocol based on a combined visual lung isolation tube versus a video double-lumen tube.BMC anesthesiology · 2026
- Progressive Extension of a Post-intubation Tracheal Laceration Presenting As Massive Pneumomediastinum: A Case Report.Cureus · 2026
- Delayed Right Hemidiaphragm Rupture After Blunt Trauma Repaired With Prolene Mesh: A Case Report.Case reports in surgery · 2026