Fabrication and Preliminary in vivo Evaluation of a Cerium Dioxide Nanoparticle-Loaded Degradable PLGA Nanofiber Dressing for Burn Wound Healing.
Shih-Heng Chen, Ching-Yu Lan, Hao-Chen Hung, Rifky Rahardian Setiawan, Shih-Jung Liu
Department of Plastic and Reconstructive Surgery, Keelung and Linkou Chang-Gung Memorial Hospital, Chang-Gung University and Medical College, Taoyuan, 33302, Taiwan. · Department of Mechanical Engineering, Chang Gung University, Taoyuan, 33302, Taiwan.
Key points
From the paper's conclusion- CeO2-loaded PLGA nanofiber dressings are biocompatible and can accelerate the intermediate phase of burn wound closure in a rat model. Because the CeO2 redox state, CeO2 release, and in vivo antioxidant mechanisms were not directly measured, the improvement cannot yet be causally attributed to CeO2, and further mechanistic studies are required.
Abstract
BACKGROUND: Conventional burn dressings maintain a moist wound environment and reduce infection but do not directly counteract the sustained oxidative stress and inflammation of the burn wound bed. Cerium dioxide (CeO2) nanoparticles possess redox-based antioxidant activity, motivating their incorporation into a resorbable dressing. This study aimed to fabricate and preliminarily evaluate CeO2-loaded poly(lactic-co-glycolic acid) (PLGA) nanofiber dressings for burn wound healing. METHODS: CeO2-loaded and pristine PLGA nanofibers were produced by electrospinning and characterized for fiber morphology, elemental composition, tensile properties, wettability, water uptake, and in vitro cytocompatibility. Wound healing was assessed in a full-thickness rat burn model over 28 days, with histological analysis at days 7 and 28. RESULTS: CeO2-incorporated nanofibers showed a smaller average fiber diameter (159.8 ± 97.6 nm) than pristine PLGA nanofibers (267.9 ± 146.3 nm). CeO2 incorporation reduced tensile strength, although all fibers retained good elongation (> 50%) before fracture. In vivo, the CeO2-loaded nanofibers produced a transient reduction in wound area that was significantly greater than the control at days 14 and 21 and greater than pristine PLGA at day 14 (p < 0.05); by day 28, wound areas had converged and the differences among groups were no longer statistically significant. Histological analysis showed earlier collagen deposition and no adverse tissue response. CONCLUSION: CeO2-loaded PLGA nanofiber dressings are biocompatible and can accelerate the intermediate phase of burn wound closure in a rat model. Because the CeO2 redox state, CeO2 release, and in vivo antioxidant mechanisms were not directly measured, the improvement cannot yet be causally attributed to CeO2, and further mechanistic studies are required.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development of PVA/chitosan nanofibrous wound dressings containing Stachys lavandulifolia extract and cerium oxide nanoparticlesScientific Reports · 2026
- Development of Electrospun Nanofibers Containing Layered Double Hydroxide/Coumarin Nanohybrid for Potential Wound HealingJournal of Biomedical Materials Research Part B Applied Biomaterials · 2026
- Construction of multifunctional cerium-containing nanozyme hydrogel and its component-level functions in skin wound healing.RSC advances · 2026
- Multifunctional DSU-g-GEL/PLGA nanofiber membrane: Orchestrating inflammation resolution and oxidative stress inhibition for skin reconstruction.International journal of biological macromolecules · 2026
- Fabrication and Healing Potential of Polylactic Acid /Clay/Nd2O3 Nanocomposite Fibers in Diabetic Wound Therapy.Macromolecular bioscience · 2026
- Ligand-metal charge transfer and photothermal carbon dots synergistically enhance cerium dioxide nanozyme activity for diabetic infected wound healingMaterials Today Bio · 2025