Development and Validation of a Logistic-Bayes Method for In-Hospital Mortality Discrimination in Neonatal Heart Failure: A Real-World Study.
Xiaoting Zhang, Meng Wei, Heyin Yang, Jixing Wu, Binghui Liu, Yanmei Lu, Baopeng Tang
Department of Cardiac Pacing and Electrophysiology, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, People's Republic of China. · Department of Cardiovascular Medicine, The First People's Hospital of Kashgar Prefecture, Kashgar, Xinjiang, People's Republic of China.
Key points
From the paper's conclusion- On internal validation, the model demonstrated high specificity and high negative predictive value, supporting early identification of low-risk neonates with heart failure; prospective multicenter validation is required before routine clinical use.
Abstract
BACKGROUND: Neonatal heart failure is a severe condition with high mortality, posing a significant burden on families and healthcare systems. Accurately discriminating whether a neonate with heart failure will die in hospital is essential for improving outcomes. OBJECTIVE: To develop and validate a discriminant model for identifying neonates with heart failure who will experience in-hospital death. METHODS: This real-world study included 600 neonates with heart failure treated at the First Affiliated Hospital of Xinjiang Medical University between 2012 and 2025. Demographic, clinical, perinatal, laboratory, and first-24-hour medication data were extracted. Candidate variables were screened by LASSO regression and between-group comparisons; eight discriminators retained by multivariable logistic regression were used to construct the Logistic-Bayes model, and the cohort was randomly split in a 7:3 ratio into training and internal validation sets. RESULTS: The final discriminators were urea, fibrinogen, poor postnatal response, oliguria, cedilanid use, dopamine use, epinephrine use, and digoxin use. The model achieved area under the receiver operating characteristic curve (AUC) values of 0.87 (95% CI 0.82-0.91) in the training set and 0.86 (95% CI 0.78-0.92) in the internal validation set, with accuracy of 0.87 in both. CONCLUSION: On internal validation, the model demonstrated high specificity and high negative predictive value, supporting early identification of low-risk neonates with heart failure; prospective multicenter validation is required before routine clinical use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical characteristics and outcomes of neonatal heart failure: a single-center retrospective analysis.Frontiers in pediatrics · 2026
- Predictive Modeling of Mortality Risk in Heart Failure Patients Using Logistic Regression Analysis of Clinical FeaturesEngineering Frontiers · 2025
- Development and external validation of an explainable machine learning model for in-hospital mortality risk stratification in intensive care unit patients with heart failure.Frontiers in cardiovascular medicine · 2026
- Machine learning-based prediction of in-hospital and post-discharge mortality in heart failure: an international retrospective study with cross-endpoint transferability analysis.Frontiers in digital health · 2026
- Development of a Nomogram Model for Predicting Mortality Risk in Critically Ill Children with Influenza.Children (Basel, Switzerland) · 2026
- Development and Validation of a Machine Learning Model for Predicting 28-Day Mortality in Patients with Sepsis-Associated Encephalopathy and Heart Failure.Journal of intensive care medicine · 2026