Successful Trastuzumab Desensitization After a Severe Infusion-Related Reaction with Acute Hypoxemia and Suspected Pulmonary Toxicity in HER2-Positive Metastatic Breast Cancer: A Case Report.
Guillermo Valencia, Andrea Stephania Calle, Patricia Rioja, Zaida Morante, Carlos Castañeda, Mariela Milla, Katherine Gutarra, Aldo Salazar,
Department of Medical Oncology, Oncosalud - AUNA, Lima, Peru. · Alergology Unit, Oncosalud - AUNA, Lima, Peru.
Key points
From the paper's conclusion- We report a 36-year-old woman with de novo HER2-positive metastatic breast cancer involving the lungs who developed hypotension, presyncope, oxygen desaturation, and acute hypoxemic respiratory failure 35 minutes after the initiation of her first trastuzumab infusion.
Abstract
Trastuzumab is a cornerstone of treatment for HER2-positive breast cancer. Infusion-related reactions are common during the first administration, but severe reactions with hemodynamic instability and acute respiratory compromise are uncommon. We report a 36-year-old woman with de novo HER2-positive metastatic breast cancer involving the lungs who developed hypotension, presyncope, oxygen desaturation, and acute hypoxemic respiratory failure 35 minutes after the initiation of her first trastuzumab infusion. Chest computed tomography showed known bilateral pulmonary metastases and new bibasal opacities, raising concern for an overlapping severe infusion-related reaction and inflammatory pulmonary toxicity. Trastuzumab was discontinued, and the patient recovered after respiratory support and systemic corticosteroids. Following complete clinical recovery and resolution of the inflammatory radiological findings, a multidisciplinary team performed a rapid drug desensitization protocol under intensive care monitoring. The full trastuzumab target dose was successfully administered without immediate or delayed breakthrough reaction, and the protocol was repeated in subsequent 12 total cycles, allowing continued HER2-targeted therapy without disease progression. This case illustrates that rapid drug desensitization may permit trastuzumab reintroduction after a severe immediate infusion-related reaction in carefully selected patients once suspected pulmonary toxicity has fully resolved. Desensitization should not be interpreted as protection against recurrent drug-induced pneumonitis and requires individualized risk-benefit assessment, allergy evaluation, pulmonary reassessment, and administration in a specialized setting.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Hypersensitivity reactions to pertuzumab/trastuzumab fixed-dose combination (PHESGO®): successful management with a simplified 9-step subcutaneous desensitization protocol.Naunyn-Schmiedeberg's archives of pharmacology · 2026
- Same-day, one-bag rapid desensitization for pertuzumab hypersensitivity: a case series.Cancer chemotherapy and pharmacology · 2026
- Use of a Desensitization Protocol in a Patient with Brentuximab Hypersensitivity: A Case Report from a Hospital in Rancagua, Chile.Revista medica de Chile · 2026
- Case Report: Delayed cutaneous toxicity following accidental extravasation of trastuzumab emtansine via peripheral venous access in a patient with HER2-positive metastatic breast cancerFrontiers in Oncology · 2026
- Case Report: Examining the role of omalizumab as an adjunct in the management of recurrent trastuzumab-associated hypersensitivity reactionsFrontiers in Oncology · 2026
- Feasibility and safety of 30-minute Trastuzumab reloading infusion in patients with HER2-positive solid tumors.Journal of oncology pharmacy practice : official publication of the International Society of Oncology Pharmacy Practitioners · 2026